Panasonic VL-V900 Installation And Operating Instructions Manual page 47

Video intercom system for apartment complexes vl-v900 and vl-v700 series
Hide thumbs Also See for VL-V900:
Table of Contents

Advertisement

Parameter
DOOR KEY OPEN CODE
DOOR KEY EXTERNAL IN
DOOR KEY IN SIGNAL
SET CAMERA
CAMERA CONNECTION
CAMERA NAME
DISPLAY PRIORITY
SWITCHING IMAGE
SET WIDE/ZOOM
WIDE/ZOOM SETTINGS
Description and available settings
Determines the door open code. If disabled, the door
cannot be opened using a code.
(4 digits, or #### to disable)
Tells the system whether an access controller (door
opener, key switch, card reader, etc.) is connected to
the lobby station and used to unlock the door.
[00]: NO
[01]: YES
Determines whether the signal received from the
access controller is a closed signal (i.e., the signal is
normally open) or an open signal (i.e., the signal is
normally closed).
[00]: CLOSE
[01]: OPEN
R Available only when "DOOR KEY EXTERNAL IN"
is set to "YES".
Tells the system whether a camera is connected or not.
[00]: NO
[01]: YES
Determines the camera name.
[01]: CAMERA #
[02]: RECEPTION
[03]: GATE
[04]: CONTROL ROOM
[05]: RESTAURANT
[06]: HALL
[07]: POOL
[08]: SECURITY OFFICE
[09]: ENTRANCE
[10]: GYM
[11]: GUEST ROOM
[12]: KID'S ROOM
[13]: PARKING
[14]: TERRACE
[15]: LIFT LOBBY
Determines which camera image is displayed when
monitoring begins.
[00]: LOBBY
[01]: CAMERA
[02]: CAMERA ONLY
Determines whether visitors (lobby station users) can
switch between the lobby station camera and the
external camera.
[00]: NO
[01]: YES
Determines whether camera images are displayed in
wide mode or in zoom mode when monitoring begins.
[00]: WIDE
[01]: ZOOM
5. Programming
Default
####
(DISABLE)
00
(NO)
00
(CLOSE)
00
(NO)
01
(CAMERA #)
00
(LOBBY)
00
(NO)
00
(WIDE)
47