ART.4800 CODELOCK INITIAL PROGRAMMING

All programming is carried out using the codelock keypad. The programming menu is
protected by an engineer's code. The factory default engineers code is 111111 (6x1). This
code can be changed to any four to eight digit code during the program but must be
different to the codes used to gain entry. Follow the flow chart to setup the system:-
Enter the engineers
code.
111111
Then press enter
Enter a new engineers
code or enter the same
engineers code again
followed by enter
Enter the access code
for relay 1 and then
press enter
Enter a two digit relay 1
time from 00 – 99 and
then press enter
More
codes?
NO
YES
Enter the access code
for relay 2 and then
press enter
Enter a two digit relay 2
time from 00 – 99 and
then press enter
More
codes?
NO
YES
Enter the access code
for relay 3 and then
press enter
Enter a two digit relay 3
time from 00 – 99 and
then press enter
Press enter twice
PAGE 9 of 40
The red LED will illuminate to acknowledge programming mode. If the red
LED does not illuminate check the master code is correct. If the master
code may have been changed from the factory default and you do not
know what it is then follow the factory default procedure on the following
page.
This code can be from 4 – 8 digits and will not activate a relay. It can only
be used to enter programming mode.
Note this new code in the box provided on the next page. It will be needed
to re-program the codes in the future.
This code will be used to open the door/gate (Relay 1). The code can be
from 4 – 8 digits long and must be different from the engineer's code.
This is the time the relay 1 will energise for. 00 will latch the relay when
the code is entered and require the code followed by clear to unlatch.
This code will be used to open the door/gate (Relay 2). The code can be
from 4 – 8 digits long and must be different from the engineer's code.
This is the time the relay 2 will energise for. 00 will latch the relay when
the code is entered and require the code followed by clear to unlatch.
This code will be used to open the door/gate (Relay 3). The code can be
from 4 – 8 digits long and must be different from the engineer's code.
This is the time the relay 3 will energise for. 00 will latch the relay when
the code is entered and require the code followed by clear to unlatch.
The red LED will go off to confirm the exit from programming mode.