Codelock Module (4800) - Videx 4000 Series Technical Manual

Gsm door intercom system
Hide thumbs Also See for 4000 Series:
Table of Contents

Advertisement

CODELOCK MODULE (4800)

The 4800 codelock includes three relay outputs, two push to exit button inputs and
operates from a 12-24V ac/dc power supply. Up to 2 unique codes can be programmed,
each in the range of 4-8 digits. Relay time can be programmed from 01 – 99 seconds or
set to latching mode with a relay time of 00 (To latch, type in the code followed by Enter, to
unlatch, type in the code followed by clear).
Connection
+
12-24V ac/dc power input
-
0V power input
C1
Common connection of relay 1 (Dry contact)
NO1
Normally open connection of relay 1 (Dry contact)
NC1
Normally closed connection of relay 1 (Dry contact)
C2
Common connection of relay 2 (Dry contact)
NO2
Normally open connection of relay 2 (Dry contact)
NC2
Normally closed connection of relay 2 (Dry contact)
C3
Common connection of relay 3 (Dry contact)
NO3
Normally open connection of relay 3 (Dry contact)
NC3
Normally closed connection of relay 3 (Dry contact)
SW1
Push to exit input for relay 1 (Triggered by 0V)
SW2
Push to exit input for relay 2 (Triggered by 0V)
PAGE 8 of 40
Art.4800 Connections
GSM DOOR INTERCOM TECHNICAL MANUAL
Function