VK8K/6458 Series "6 wire Bus" videokit
Art. 8800 - Art. 8800-3
PROGRAMMING
• Enter ENGINEER'S CODE: first time type six times 1 (111111
factory preset) and press ENTER (The red LED will illuminate).
• Confirm ENGINEER'S CODE (typing again the same) or
type the new code (4 to 8 digits) then press ENTER (Melo-
dy). Pressing twice the ENTER button without changing the
ENGINEER'S CODE, will exit from the programming.
• Enter the code (4 to 8 digits) to enable RELAY 1 (ACCESS 1) or
re-enter the existing code then press ENTER (Melody).
• Enter the RELAY 1 operation time (2 digits 01 to 99 I.E. 05=5
seconds, 00= remain open time) or re-enter the existing time
then press ENTER (Melody).
• Enter the code (4 to 8 digits) to enable RELAY 2 (ACCESS 2) or
re-enter theexisting code then press ENTER (Melody).
• Enter the RELAY 2 operation time (2 digits 01 to 99 I.E. 05=5
seconds, 00=remain open time) or re-enter the existing time
then press ENTER (Melody).
• Enter the code (4 to 8 digits) to enable RELAY 3 (ACCESS 3
only for Art. 8800-3) or re-enter the existing code then press
ENTER (Melody).
• Enter the RELAY 3 (only for Art. 8800-3) operation time (2 dig-
its 01 to 99 I.E. 05=5 seconds, 00=remain open time) or re-en-
ter the existing time then press ENTER (Melody).
• The system is ready to use (the red LED will be off ).
RETURN SYSTEM TO PRESET ENGINEER'S FACTORY CODE
• Turn off power to code lock;
• Keep ENTER button pressed while turning the power back on;
• Release ENTER button;
• The engineer's code is now set to 111111 (six times one).
OPERATION
To use the system, type in the programmed code and press ENTER, the green LED will illuminate and the relay will operate for the
programmed time.To cancel remain open time, type in the same code and press CLEAR. If a wrong code is entered, a continuous
melody will sound for 4 or more seconds, according to the number of mistakes.
OPERATION NOTES
• To operate relays together, set the same code for each relay;
• If a wrong code is entered, the system will lock out for 5 seconds which will increase each time a wrong code is entered. The system will
operate only when the correct code is enter
VK8K/6458 Series - Installation handbook
Digital codelock module
"ENGINEER'S CODE"
Press Enter
(Red LED will
be ON)
Press Enter
"ENGINEER'S CODE"
(melody)
"ACCESS 1 CODE"
Press Enter
(melody)
"ACCESS 1 TIME"
Press Enter
(melody)
"ACCESS 2 CODE"
Press Enter
(melody)
"ACCESS 2 TIME"
Press Enter
(melody)
"ACCESS 3 CODE"***
Press Enter
(melody)
"ACCESS 3 TIME"***
Press Enter
(melody)
READY TO USE
*** Only for Art. 8800-3
- 10 -
First time six times
ENTER THE
1 "111111" factory
preset
Type again six times
CONFIRM
"1" or the new en-
OR CHANGE
gineer's code 4 to 8
digits
ENTER
Code to enable relay 1
4 to 8 digits
Two digits (01 to 99)
ENTER
i.E. 05=5 Seconds
00= remain open
ENTER
Code to enable relay 2
4 to 8 digits
Two digits (01 to 99)
ENTER
i.E. 05=5 Seconds
ENTER
Code to enable relay 3
4 to 8 digits
ENTER
Two digits (01 to 99)
i.E. 05=5 Seconds
SYSTEM
Red led will be off
66250863-EN - V4.0 - 15/03/19