Art. 4800 - 4800M Digital Codelock Module - Videx 6358 Installation Handbook

“6 wire” bus one way, two way videokit
Hide thumbs Also See for 6358:

Advertisement

VK4K/6358 Series "6 wire Bus" videokit
Art. 4800M
Digital codelock module
BUZZER BACK EMF
When using intercoms with buzzer call (Art.924/926, SMART1/2, 3101/2, 3001/2 and 3021/2) add one 0.1uF (100nF) capacitor be-
tween terminals 3 and 6 on the telephone.
BUILT-IN RELAYS – BACK EMF PROTECTION
The Art. 4800M includes selectable back EMF protection on the relays. The jumpers marked MOV (One jumper for each relay) are
used to select the protection type. When using a fail secure lock with connections C & NO the jumper should be in the NO position.
When using a fail open lock with connections C & NC the jumper should be in the NC position and when using the codelock to
trigger a gate controller or another third party controller the jumper should be removed completely (This disables the protection
on the relay).
PROGRAMMING (SEE ALSO THE RELEVANT FLOW CHART)
Enter the "ENGINEER'S CODE": first time type six times "1" (111111 factory preset) and press "ENTER" (The red LED will illuminate);
Confirm "ENGINEER'S CODE" (typing again the same) or type the new code (4 to 8 digits) then press "ENTER" (Melody). Pressing
twice the "ENTER" button without changing the "ENGINEER'S CODE", will exit from the programming;
Enter the code (4 to 8 digits) to enable "RELAY 1" or re-enter the existing code then press "ENTER" (Melody);
Enter the "RELAY 1" operation time (2 digits 01 to 99 I.E. 05=5 seconds, 00= remain open time) or re-enter the existing time then
press "ENTER" (Melody);
Enter the code (4 to 8 digits) to enable "RELAY 2" or re-enter the existing code then press "ENTER" (Melody);
Enter the "RELAY 2" operation time (2 digits 01 to 99 I.E. 05=5 seconds, 00= remain open time) or re-enter the existing time then
press "ENTER" (Melody);
Enter the code (4 to 8 digits) to enable "RELAY 3" or re-enter the existing code then press "ENTER" (Melody);
Enter the "RELAY 3" operation time (2 digits 01 to 99 I.E. 05=5 seconds, 00= remain open time) or re-enter the existing time then
press "ENTER" (Melody);
The system is ready to use (the red LED will be off ).
PROGRAMMING NOTES
After pressing enter following a command, press "ENTER" a further twice to exit the programming menu.
RETURN SYSTEM TO PRESET ENGINEER'S FACTORY CODE
Turn off power to code lock;
Keep "ENTER" button pressed while turning the power back on;
Release "ENTER" button;
The engineer's code is now set to "111111" (six times one).
OPERATION
Type in the programmed code and press "ENTER";
If the code is correct, the green LED will illuminate for ap-
prox. 2 seconds and the relay relevant to the code will oper-
ate for the programmed time;
If a wrong code is entered, a continuous melody will sound
for 4 or more seconds, according to the number of mistakes;
To switch off any relay while operating, type in the relevant
code then press the "CLEAR" button;
OPERATION NOTES
To operate relays together, set the same code for each relay;
If a wrong code is entered, the system will lock out for 5 sec-
onds which will increase each time a wrong code is entered.
The system will operate only when the correct code is entered.
VK4K/6358 Series - Installation handbook
TERMINALS:
SW2
Relay 2 command signal (active low)
SW1
Relay 1 command signal (active low)
NC3
Relay 3 normally closed contact
NO3
Relay 3 normally open contact
C3
Relay 3 common contact
NC2
Relay 2 normally closed contact
NO2
Relay 2 normally open contact
C2
Relay 2 common contact
NC1
Relay 1 normally closed contact
NO1
Relay 1 normally open contact
C1
Relay 1 common contact
12/24Vac/dc power input
+
11
Max
24Vac/dc
3A
66251400-EN - V 3.4 - 31/08/16