Event Counter At Port Level - Hirschmann MACH 4000 User Manual

Industrial ethernet (gigabit) switch
Hide thumbs Also See for MACH 4000:
Table of Contents

Advertisement

Operation diagnosis

9.5 Event counter at port level

The port statistics table enables experienced network administrators to iden-
tify possible problems in the network.
This table shows you the contents of various event counters. In the Restart
menu item, you can reset all the event counters to zero using "Warm start",
"Cold start" or "Reset port counter".
The counters add up the events sent and the events received.
Counter
Received fragments
CRC error
Collisions
Table 16: Examples indicating possible problems
Select the Diagnostics:Ports:Statistics dialog.
To reset the counters, click on "Reset port counters" in the Ba-
sics:Restart dialog.
Basic - L3P
Release 4.0 11/07
Possible problem
– The controller of the connected device is faulty – Electromagnetic
interference in the transmission medium
– The controller of the connected device is faulty – Electromagnetic
interference in the transmission medium - Defective component in
the network
– The controller of the connected device is faulty – Network overex-
tended/lines too long – Collision of a fault with a data packet