EMC interference
immunity
EN 61000-4-5
EN 61000-4-6
EMC emitted
interference
EN 55022
FCC 47 CFR Part 15 Class A
Stability
Stability
Vibration
Shock
Shock resistance
BAT54-F X2 and
BAT54-F X2 FCC
Radio standards
EN 300 328
EN 301 893
EN 301 489-1
EN 301 489-17
Network range
TP port
Length of a twisted pair segment
Table 8:
TP port 10BASE-T / 100BASE-TX / 1000BASE-T
60
Voltage surges
- Power line, line/line: test level 2
- Power line, line/earth: test level 3
- Data line: test level 3
Conducted interference voltages, test level 3
150 kHz - 80 MHz
Class A
IEC 60068-2-6 Test FC test level according to IEC 61131-2
IEC 60068-2-64 test level in accordance with EN 50155:2001+A1:2002
IEC 60068-2-27 Test Ea test level in accordance with IEC 61131-2,
EN 50155:2001+A1:2002
IEC 60079-0 chap. 6.2
Shock resistance test with 1kg mass dropped from 0.7 m
Housing cover only removeable with tool
Electromagnetic compatibility and radio spectrum matters (ERM) -
bandwidth transfer systems - data transmission equipment operating in
2.4 GHz ISM band and using spread spectrum modulation technology
Broadband radio access networks (BRAN) - 5 GHz high-performance
Remote Local Area Network (RLAN)
Electromagnetic compatibility for radio equipment and services
Electromagnetic compatibility (EMC) for radio equipment and services -
specific conditions for 2.4 GHz wideband transmission systems and 5
GHz high-performance RLAN equipment
max. 100 m / 300 ft (cat5e cable with 1000BASE-T)
BAT...
0,5 kV
1 kV
1 kV
10 V
BAT-F, BAT-Rail, BAT54, BAT300
Release 02 07/10
BAT300
-Rail
1 kV
3 V