Overload current
protection at input
Insulation voltage
between operating
voltage connectors
and housing
Environment
Storage temperature
Humidity
Atmospheric pressure
Operating
BAT-Rail
temperature
BAT-F
Pollution degree
BAT-Rail
Protection class
BAT-F: IP 67
BAT-Rail: IP 40
Radio technology
Antenna
BAT54-F
connection
BAT54-F Single
BAT54-F Client
BAT300-F
BAT54-Rail
BAT54-Rail Single Two Reverse SMA antenna connections (sockets)
BAT54-Rail Client Two Reverse SMA antenna connections (sockets)
BAT300-Rail
Range
BAT...
Encryption
BAT...
Frequency
BAT54
range
BAT300
BAT...BG(N)
Modulation
BAT...
technology
58
(ambient air
temperature)
Four antenna connections
Two antenna connections
Two antenna connections
Three antenna connections
Four Reverse SMA antenna connections (sockets)
Three Reverse SMA antenna connections (sockets)
Up to 20 km with external antennas (depending on antenna
used, frequency range and data rate)
IEEE802.11i/WPA2 with passphrase or 802.1x and
hardware-accelerated AES, user authentication with
802.1x/EAP or LEPS, IEEE 802.1x supplicant in client
mode, WPA/TKIP, WEP, access control lists, WLAN port
and protocol filters, RADIUS client and server, built-in
firewall with QoS, port filter, protocol filter, IDS and DoS
protection, PMK caching and pre-authentication for fast
roaming with IEEE802.1x
2 x (1 x for BAT-Client types) independent radio modules,
each 2.4 Ghz and 5 GHz: 2400-2483.5 MHz (ISM) and
5170-5810 MHz
1 x radio module, supported by 2.4 GHz and 5 GHz: 2400-
2483.5 MHz (ISM) and 5170-5850 MHz
Supports 2.4 GHz: 2400-2483.5 MHz (ISM)
22M0F7D (DSSS/OFDM) at 2.4 GHz
20M0G7D (OFDM) at 5 GHz
Non-replaceable fuse
800 V DC
Protective elements limit the insulation voltage to
45 V DC.
-30 °C to +70 °C ( -22 °F to +158 °F)
10% to 95% (non-condensing)
up to 2,000 m (795 hPa)
Ambient air -30 °C to +50 °C
(temporarily up to +70 °C acc. to EN50155)
Ambient air -30 °C to +55 °C
(temporarily up to +70 °C acc. to EN50155)
2
Sturdy metal housing
- designed for mounting on a pole or on a flat
surface (e.g. wall)
- designed for mounting on a DIN rail or on a flat
surface (e.g. wall)
BAT-F, BAT-Rail, BAT54, BAT300