Figure
8
6
7
4
5
3
2
1
U
Table 7: Pin assignment of the V.24 interface for BAT-Rail (miniDin socket)
Note: You will find the order number for the terminal cable, which is
ordered separately, in the "Technical Data" chapter
„Technical
data").
2.20

Disassembly

To remove the device from the DIN rail, press the device downwards and
pull it out from under the DIN rail.
Figure 22: Removal from the DIN rail
56
Pin
Function
1
CTS
2
RTS
3
RxD
4
RI
5
TxD
6
DSR
7
DCD
8
DTR
U
GND
Clear to send
Request to send
Receive data
Ring indicator
Transmit data
Dataset ready
Data carrier detect
Data terminal ready
Ground
(see on page 57