OSEE XCM-250-OLED User Manual page 61

Critical evaluation and grading monitor
Table of Contents

Advertisement

 The INTERLACE MODE function is not available in PIP, PBP, WIPE, FLIP,
or BLENDING mode.
 The INTERLACE MODE function is available for SDI inputs.
 FLIP Mode
The input signal has been inverted horizontally by a mirror type in FLIP
Display mode.
Select the menu item CONFIG SDI ASSIST MODEN to be set to H FLIP,
thus to inverse these inputs horizontally.
The display result in the Horizontal FLIP MODE is as shown in Figure
5.1-30:
 The H FLIP MODE function is not available in WIPE, INTERLACE, or
BLENDING mode.
 The Wave Form of the input signal in H FLIP mode will not be inversed
horizontally.
Screen Saver
3.
The Screen Saver function is used to detect a still image on the screen, in
order to protect the screen of the monitor
 ON: When a still image is displayed on the screen for 10 minutes or
more, the brightness of the screen is automatically reduced to its
lowest to prevent burn-in of the screen(Contrast=0). The brightness
returns to normal if you input a moving image or operate any key on
OFF
Figure 5.1-30 Horizontal Flip Mode
55