Preparing Motor Cables (Servo Amplifier End); Preparing Cables For S300/S400 - Kollmorgen SERVOSTAR 300 Manual

Hide thumbs Also See for SERVOSTAR 300:
Table of Contents

Advertisement

11.11.4 Preparing motor cables (servo amplifier end)

Material list
Part
Cable
Connector kit amplifier end S300, 230V
Connector kit amplifier end S300, 400V
Connector kit amplifier end S400
Connector kit amplifier end S601...620
Connector kit amplifier end S701-712,S724 Power Combicon X9 DE-200453
Connector kit amplifier end
AKD-x00306/x00606*, SK14
Connector kit amplifier end
AKD-x01206/x02406/x0xx07*
*= X means variants -B, -P, -T and -M
Connection scheme
Pin assignment is described in the instructions manual for the servo amplifier.

11.11.4.1 Preparing cables for S300/S400

The motor is connected to S300 or S400 by a Power Combicon connector (➜ p. 77). Please
take note that the connector can accept a maximum conductor cross-section of 4 mm².
Accessories Europe | 11   Cables
Description
Order code
Overview (➜ p. 45)
Power Combicon X9 DE-107631
Power Combicon X9 DE-107467
Power Combicon X6 DE-107466
Power Combicon X9 DE-90066
Power Combicon X2 AKD-X2+SK14-Kit
Power Combicon X2 AKD-X2+Shield-Kit
Strip the external cable sheath to a length of
approximately 120 mm, taking care not to
damage the braided shield. Push the braided
shield (1) back over the cable and secure
with a rubber sleeve (2) or shrink sleeve.
Shorten all the wires apart from the protective
earth (PE) wire (green/yellow) by about 20
mm so that the PE wire is now the longest
wire. Strip all wires and fit wire end ferrules.
Wire the connector as shown in the con-
nection diagram in the instructions manual.
Plug in the connector to the socket on the
front of the servo amplifier. Screw the con-
nector in place.
Use a shielding clamp (➜ p. 24) to ensure an
optimum shield connection to the servo amp-
lifier.
Alternatively you can use the shield shroud of
the servo amplifier. Use cable ties to attach
the cable to the side shroud of the amplifier,
securing the braided shield of the cable to
the shroud with a cable tie.
This ensures that there is conductive contact
over a large surface area between the
braided shield and the front panel.
Kollmorgen | December 2014
77

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Servostar 400Servostar 601...620Servostar 640...670

Table of Contents