Accessories Europe | 11 Cables
Preparing shielded cables
First, remove the outer cov-
ering of the cable and the
shielding braid over a length
of about 70 mm. Then
remove just the outer cov-
ering for about another
50 mm, without damaging
the shielding braid.
Strip off about 10 mm of the
insulation from the ends of
the cores. Take care to
avoid damage to the copper
strands while doing this.
Depending on the cross-sec-
tion of the core and the type
of bootlace ferrule that is
used, the length that has to
be stripped may vary by sev-
eral millimeters.
Apply bootlace ferrules to
the conductors. As an altern-
ative, you can also use ter-
minal pins instead of
bootlace ferrules.
Connector example S600:
Push the ends of the con-
ductors into the connector
as far as they will go. Follow
the pin assignment in the
instructions manual. Tighten
the screws of the terminals.
Take care that the insulation
is not trapped in the ter-
minals.
50