Technical Specification - Parker 514C-04 Technical Manual

Dc controller 514c series
Hide thumbs Also See for 514C-04:
Table of Contents

Advertisement

TECHNICAL SPECIFICATION

General
SPEED CONTROL
Control Action
Speed Feedback
100% Load Regulation
Maximum Torque/Speed Range
Overload
TORQUE CONTROL
Control Action
Accuracy
Overspeed
Overload
INPUTS / OUTPUTS
Analogue
Setpoint Ramp
Inputs
Positive Trim Setpoint
Negative Trim Setpoint
Current Limit
Current Demand
Tachogenerator Input
Thermistor /
Microtherm Input
Outputs
Setpoint Ramp
Analogue
Total Setpoint
Speed
Current Demand
Current Meter
Bipolar or Modulus
+10V Reference
-10V Reference
Digital
Run
Inputs
Enable
Stall Override
Digital
Health
Outputs
Zero Speed or Setpoint
514C Product Manual
This manual was downloaded on www.sdsdrives.com
+44 (0)117 938 1800 - info@sdsdrives.com
Closed Loop with Proportional Integral Control and
Adjustable Stability
Armature Voltage
2 % Typical
20:1
150% for 60 seconds.
Closed Loop with Proportional Integral Control.
2 %
Inherent.
None 100% continuous (consideration must be given
to motor when operating at low speed).
0 to ±10V
0 to ±10V
0 to ±10V
0 to +7.5V
0 to ±10V
0 to ±350Vdc
<200 ohm = Normal
>1800 ohm = Overtemperature
0 to ±10V
0 to ±10V
0 to ±10V
0 to ±10V
0 to ±5V (0 to Ical)
See SW1/8
+10V
- 10V
+10 to +24V
+10 to +24V
+10
+24V
+24V
Product Overview
Tachogenerator
0.1 % Typical
100:1
100 Kohm
100 Kohm
100 Kohm
50 Kohm
100 Kohm
220 Kohm
5 Kohm
5 mA
5 mA
5 mA
5 mA
5 mA
5 mA
5 mA
100 Kohm
100 Kohm
100 Kohm
50 mA Source
50 mA Source
1-3

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

514c-08514c-16514c-32514c