1-4
Product Overview
Electrical Ratings
INPUT RATINGS
Supply Voltage
Maximum Supply
Voltage (Derived from
Three Phase Supply)
Supply Current
Supply Frequency
Auxiliary Supply
Aux. Supply Current
Contactor Coil
Current
Installation Category
Earth Leakage
Current at 480Vac
OUTPUT RATINGS
Nominal Armature
Voltage
Maximum Armature
Current
Armature Current
Calibration 100%
Nominal Motor Power
at 320 Vdc Armature
Overload
Field Current
Field Voltage
Maximum Armature
Form Factor
Thyristor I
t
2
Typical Controller
Dissipation at Ia 100%
UL Listed Rating @
180V dc
Notes:-
(1)
Permanent earthing mandatory.
(2)
See page 3-2 for filter watt loss information.
This manual was downloaded on www.sdsdrives.com
+44 (0)117 938 1800 - info@sdsdrives.com
SYMBOL
514C-04
Vs
Is
6A
fs
Vaux
Iaux
Va
Ia
4A dc 10% 8A dc 10% 16A dc 10% 32A dc 10%
Ical
0.1 to 4A
in 0.1A steps
Pm
1.125kW
1
HP
1
/
HP
2
If
Vf
(2)
15W
HP
1
/
HP
2
514C-08
110 - 480 Vac  10%
480Vac L - L Non earth referenced (IT)
or earth referenced (TN)
480Vac L - N Earth referenced (TN)
12A
50/60 Hz ñ 5 Hz
110/120 or 220/240 Vac ±10%
3A (Includes Contactor Coil Current)
3A Maximum
Overvoltage Category III
Without Filter
-
With Filter
-
90 Vdc at 110/120 Vac
180 Vdc at 220/240 Vac
320 Vdc at 380/415 Vac
0.1 to 8A
0.1 to 16A
in 0.1A steps
2.25 kW
3 HP
150% for 60 seconds
3 A dc
0.9 X Supply Voltage (Vs)
1.5
300 A
(2)
25W
1 HP
514C-16
514C-32
24A
48A
(1)
5mA
50mA
0.1 to 32A
in 0.1A
in 0.1A steps
steps
4.5 kW
9 kW
6 HP
12 HP
s
2
(2)
50W
75W
3 HP
5 HP
514C Product Manual