Appendix A

IQAN-XS2 Technical Overview

Absolute Maximum Ratings
Parameter
Ambient temperature, T
A
Storage temperature
Voltage supply on +BAT
Voltage on any pin with respect to -BAT
Maximum current into -VREF
Maximum current sourced by all outputs
a.
The "Absolute Maximum Ratings" table lists the maximum limits to which the device can be subjected
without damage. This doesn´t imply that the device will function at these extreme conditions, only
that, when these conditions are removed and the device operated within the "Recommended Operating
Conditions", it will still be functional and its useful life won't have been shortened.
Environmental ratings
Parameter
EMI
ISO 14982:1998, Radiated emission
EN 55025:2003, Conducted emission
ISO 11452-2:1995, Radiated Susceptilbility
ISO 11452-4:2001, Conducted Susceptibility
ISO 7637-2:2004, Conducted transient susceptibility on power
ISO 7637-3:1995, Conducted transient susceptibility on signal
ESD
ISO 10605:2001, ESD
Mechanical environment
IEC 60068-2-64:1993 Fh, Random vibration
IEC 60068-2-29:1987 Eb, Bump
Climate environment
IEC 60529:2001, Enclosure protection
DIN 40050 Part 9:1993, Enclosure protection
IEC 60068-2-30:1985 Db, Damp heat cyclic
IEC 60068-2-78:2001, Damp heat, steady state
IEC 60068-2-14:1984 Nb, Change of temperature
Chemical environment
IEC 60068-2-52:1996 Kb, Salt mist
Instruction book, IQAN-XS2
a
IQAN-XS2 Technical Overview
Appendix A
Remark
-40 °C to +85 °C
-40 °C to +100 °C
6 - 34 V
34 V with external 20 A fuse
(for reverse polarity protection)
2 A
<20 A
Remark
30-1000 MHz
0.15-108 MHz, class 1
20-1000 MHz, 100V/m
1-200 MHz, 150mA
1,2a,2b,3a,3b,4, 5
80V
15KV, air,
8 KV contact
4 KV handling
0.4 g²/Hz, 15- 250 Hz, 10 hours
40g, 6 ms,1000 in each direction
IP66: 100 l/min, 3min
IP6K9K: 1000kPa, +80°C, 30sec
55°C, 6 cycles
40°C, 93% RH, 21 days
-40°C to 70°C, 100 cycles
3 days
22