Table 4-13 Affinity Emc Filter Cross Reference; Table 4-14 Ip54 Emc Filter Cross Reference - Emerson Affinity User Manual

Building automation hvac/r drive
Table of Contents

Advertisement

Safety
Product
Mechanical
Information
Information
Installation
In order to ensure the installation meets the various emission standards
described in:
The EMC data sheet available from the supplier of the drive
The Declaration of Conformity at the front of this manual
Chapter 12 Technical data on page 228
...the correct external EMC filter must be used and all of the guidelines in
section 4.11.3 General requirements for EMC and section
4.11.5 Compliance with generic emission standards must be followed.

Table 4-13 Affinity EMC filter cross reference

Drive
BA1201 to BA1202
BA1203 to BA1204
BA2201 to BA2203
BA3201 to BA3202
BA4201 to BA4203
BA5201 to BA5202
BA1401 to BA1404
BA1405 to BA1406
BA2401 to BA2403
BA3401 to BA3403
BA4401 to BA4403
BA5401 to BA5402
BA6401 to BA6402
BA3501 to BA3507
BA4601 to BA4606
BA5601 to BA5602
BA6601 to BA6602

Table 4-14 IP54 EMC filter cross reference

Drive
BA1201 to BA1202
BA1203 to BA1204
BA1401 to BA1404
BA1405 to BA1406
BA2201 to BA2203
BA2401 to BA2403
BA3201 to BA3202
BA3401 to BA3403
BA3501 to BA3502
High ground leakage current
When an EMC filter is used, a permanent fixed ground
connection must be provided which does not pass through a
connector or flexible power cord. This includes the internal
WARNING
EMC filter.
N
NOTE
The installer of the drive is responsible for ensuring compliance with the
EMC regulations that apply where the drive is to be used.
4.11.1
Grounding hardware
The drive is supplied with a grounding bracket, and sizes 1 to 3 with a
grounding clamp, to facilitate EMC compliance. They provide a
convenient method for direct grounding of cable shields without the use
of "pig-tails". Cable shields can be bared and clamped to the grounding
bracket using metal clips or clamps
that the shield must in all cases be continued through the clamp to the
intended terminal on the drive, in accordance with the connection details
for the specific signal.
1
A suitable clamp is the Phoenix DIN rail mounted SK14 cable clamp
(for cables with a maximum outer diameter of 14mm).
Affinity User Guide
Issue Number: 5
Electrical
Getting
Basic
Running
Installation
Started
parameters
the motor
Schaffner
Epcos
CT part no.
CT part no.
4200-6118
4200-6121
4200-6119
4200-6120
4200-6210
4200-6211
4200-6307
4200-6306
4200-6406
4200-6405
4200-6503
4200-6501
4200-6118
4200-6121
4200-6119
4200-6120
4200-6210
4200-6211
4200-6305
4200-6306
4200-6406
4200-6405
4200-6503
4200-6501
4200-6603
4200-6601
4200-6309
4200-6308
4200-6408
4200-6407
4200-6504
4200-6502
4200-6604
4200-6602
CT part no.
4200-6125
4200-6124
4200-6125
4200-6124
4200-6218
4200-6218
4200-6319
4200-6318
4200-6320
1
(not supplied) or cable ties. Note
www.controltechniques.com
SMARTCARD
Optimization
PC tools
operation
See Figure 4-15 and Figure 4-16 for details on installing the grounding
clamp.
See Figure 4-17 for details on installing the grounding bracket.
Figure 4-15 Installation of grounding clamp (size 1 and 2)
Figure 4-16 Installation of grounding clamp (size 3)
Figure 4-17 Installation of grounding bracket (sizes 1 to 6)
Advanced
Technical
Diagnostics
parameters
Data
UL Listing
Information
79

Advertisement

Table of Contents
loading

Table of Contents