Safety
Product
Mechanical
Information
Information
Installation
9
Analog output 1
10
Analog output 2
Terminal 9 default function
Terminal 10 default function
Type of output
Mode controlled by...
Operating in Voltage mode (default)
Voltage range
Maximum offset
Maximum output current
Load resistance
Protection
Operating in current mode
Current ranges
Maximum offset
Maximum open circuit voltage
Maximum load resistance
Common to all modes
Resolution
Update period
11
0V common
Function
21
0V common
Function
22
+24V user output (selectable)
Terminal 22 default function
Programmability
Nominal output current
Maximum output current
Protection
23
0V common
Function
Affinity User Guide
Issue Number: 5
Electrical
Getting
Basic
Running
Installation
Started
parameters
the motor
OL> Motor FREQUENCY output signal
CL> SPEED output signal
Motor active current
Bipolar single-ended analog voltage or
unipolar single ended current
Pr 7.21 and Pr 7.24
±10V +3%
±200mV
±35mA
Ω
1k
min
35mA max. Short circuit protection
0 to 20mA±5%
4 to 20mA ±5%
μ
600
A
+15V
Ω
600
10-bit (plus sign in voltage mode)
μ
250
s when configured as a high speed
output with sources as Pr 4.02 , Pr 4.17 in
all modes or Pr 3.02 , Pr 5.03 in RFC mode.
4ms when configured as any other type of
output or with all other sources.
Common connection for all external
devices
Common connection for all external
devices
+24V user output
Can be switched on or off to act as a fourth
digital output (positive logic only) by setting
the source Pr 8.28 and source invert Pr
8.18
200mA (including all digital I/O)
240mA (including all digital I/O)
Current limit and trip
Common connection for all external
devices
www.controltechniques.com
SMARTCARD
Optimization
PC tools
operation
24
Digital I/O 1
25
Digital I/O 2
26
Digital I/O 3
Terminal 24 default function
Terminal 25 default function
Terminal 26 default function
Type
Input / output mode controlled by...
Operating as an input
Logic mode controlled by...
Absolute maximum applied voltage
range
Impedance
Input thresholds
Operating as an output
Open collector outputs selected
Nominal maximum output current
Maximum output current
Common to all modes
Voltage range
Sample / Update period
27
Digital Input 4
28
Digital Input 5
29
Digital Input 6
Terminal 27 default function
Terminal 28 default function
Terminal 29 default function
Type
Logic mode controlled by...
Voltage range
Absolute maximum applied voltage
range
Impedance
Input thresholds
Sample / Update period
30
0V common
Function
31
Drive enable
Type
Voltage range
Absolute maximum applied voltage ±30V
Thresholds
Response time
Advanced
Technical
Diagnostics
parameters
Data
DRIVE ACTIVE output
DRIVE RESET input
RUN FORWARD input
Positive or negative logic digital inputs,
positive or negative logic push-pull outputs
or open collector outputs
Pr 8.31 , Pr 8.32 and Pr 8.33
Pr 8.29
±30V
Ω
6k
10.0V ±0.8V
Pr 8.30
200mA (total including terminal 22)
240mA (total including terminal 22)
0V to +24V
μ
250
s when configured as an input with
destinations as Pr 6.35 or Pr 6.36 . 600
when configured as an input with
destination as Pr 6.29 . 4ms in all other
cases.
FIRE MODE ACTIVATE input
Analog INPUT 1 / INPUT 2 select
Unassigned input
Negative or positive logic digital inputs
Pr 8.29
0V to +24V
±30V
Ω
6k
10.0V ±0.8V
μ
250
s with destinations as Pr 6.35 or
μ
Pr 6.36 . 600
s with destination as Pr 6.29 .
4ms in all other cases.
Common connection for all external
devices
Positive logic only digital input
0V to +24V
15.5V ±2.5V
Nominal: 8ms
Maximum: 20ms
UL Listing
Information
μ
s