Safety
Product
Mechanical
Information
Information
Installation
Parameter
5.01
Output frequency
5.02
Output voltage
5.03
Output power
5.04
Motor rpm
5.05
D.C bus voltage
5.06
Rated frequency
5.07
Motor rated current
5.08
Rated load rpm / rated speed
5.09
Rated voltage
5.10
Rated power factor
5.11
Number of motor poles
5.12
Autotune
Dynamic V/F / flux optimise
5.13
select
5.14
Voltage mode select
5.15
Low frequency voltage boost
5.17
Stator resistance
5.18
Maximum switching frequency
High stability space vector
5.19
modulation
5.20
Quasi-square enable
5.21
Field gain reduction
5.23
Voltage offset
σ
5.24
Transient inductance (
L
s
Stator inductance (L
)
5.25
s
High dynamic performance
5.26
enable
5.27
Enable slip compensation
Field weakening compensation
5.28
disable
5.29
Motor saturation breakpoint 1
5.30
Motor saturation breakpoint 2
5.31
Voltage controller gain
Motor torque per amp, K
5.32
t
Disable auto switching
5.35
frequency change
5.37
Actual switching frequency
5.40
Spin start boost
RW Read / Write
RO
Read only
FI
Filtered
DE
Destination
162
Electrical
Getting
Basic
Installation
Started
parameters
OL
±SPEED_FREQ_
{0.11}
MAX Hz
0 to AC_voltage_max V
{0.10}
±180,000 rpm
0 to +DC_voltage_max V
{0.47}
0 to 3,000 Hz
{0.46}
0 TO RATED_CURRENT_MAX A
{0.45}
0 to 180,000 rpm
{0.44}
0 to AC_VOLTAGE_SET_MAX V
{0.43}
{0.42}
Auto to 120 Pole (0 to 60)
{0.40}
0 to 2
{0.09}
OFF (0) or On (1)
Ur_S (0), Ur (1),
{0.07}
Fd (2), Ur_Auto (3), Ur_I
(4), SrE (5)
{0.08}
0.0 to 25.0 % of motor rated voltage
Size 1 to 5: 0.000 to 65.000
Size 6: 0.000 to 65.000 x 10 m
{0.41}
3 (0), 4 (1), 6 (2), 8 (3), 12 (4), 16 (5) kHz
OFF (0) or On (1)
0.0 to 25.0 V
)
OFF (0) or On (1)
3 (0), 4 (1), 6 (2), 8 (3), 12 (4), 16 (5), 6 rEd (6), 12 rEd (7)
{0.18}
Uni
Unipolar
Bi
NC
Not copied
RA
www.controltechniques.com
Running
SMARTCARD
Optimization
the motor
operation
Range( )
RFC
±1,250.0 Hz
±Power_max kW
0 to 1,250.0 Hz
0.00 to 40,000.00 rpm
0.000 to 1.000
0 to 4
Ω
Ω
OFF (0) or On (1)
0.000 to 500.000 mH
0.00 to 5,000.00 mH
OFF (0) or On (1)
OFF (0) or On (1)
0 to 100% of rated flux
0 to 30
0.00 to 500.00
-1
N m A
OFF (0) or On (1)
0.0 to 10.0
Bi-polar
Bit
Bit parameter
Rating dependent
PT
Protected
Advanced
Technical
PC tools
Diagnostics
parameters
Data
Default( )
OL
RFC
RO
Bi
RO Uni FI
RO
Bi
RO
Bi
RO Uni FI
EUR> 50.0, USA> 60.0
RW Uni
RATED_CURRENT_MAX RW Uni
EUR>
EUR>
1,500
1,450.00
RW Uni
USA>
USA>
1,800
1,770.00
200V drive: 230
400V drive: EUR> 400
USA> 460
RW Uni
575V drive: 575
690V drive: 690
0.850
RW Uni
Auto (0)
RW Txt
0
RW Uni
OFF (0)
RW Bit
Fd (2)
RW Txt
Size 1 to 3: 3.0
Size 4 & 5: 2.0
RW Uni
Size 6: 1.0
0.0
RW Uni
3 (0)
RW Txt
RW Bit
OFF (0)
RW Bit
OFF (0)
RW Bit
0.0
RW Uni
0.000
RW Uni
0.00
RW Uni
OFF (0)
RW Bit
On (1)
RW Bit
OFF (0)
RW Bit
50
RW Uni
75
RW Uni
1
RW Uni
RO Uni
OFF (0)
RW Bit
RO Txt
1.0
RW Uni
Txt
Text string
US
User save
PS
Affinity User Guide
UL Listing
Information
Type
FI
NC PT
NC PT
FI
NC PT
FI
NC PT
NC PT
US
RA
US
US
RA
US
RA
US
US
NC
US
US
US
RA
US
RA
US
US
US
US
RA
US
RA
US
RA
US
US
US
US
US
US
US
US
US
NC PT
US
Power down save
Issue Number: 5
Need help?
Do you have a question about the Affinity and is the answer not in the manual?
Questions and answers