Signal line name
DTS ON
BTR MONITOR
BTR SEL
BTR REMOTE
BCR AC CLOCK
BCR AC ON
BCR DC REMOTE
DEVE BIAS DC REMOTE
DEVE BIAS DC ON
ATC SENSOR SIGNAL
HUMIDITY SIGNAL
TEMP SIGNAL
DISPENSE MOTOR ON(L) +24VDC
5 Drive / CRUM
Description
ON/OFF control signal of DTS output
Voltage monitor signal of BTR output (analog value)
Polarity switching signal of BTR output
Current control signal of BTR DC output (analog value)
Clock signal od BCR AC output
ON/OFF control signal of BCR AC output
ON/OFF control signal of BCR DC output (analog value)
DEVE BIAS DC voltage output signal
ON/OFF control signal of DEVE BIAS DC output
Toner concentration in the developing unit detection signal
(analog value) measured by ATC Sensor in CRU
Humidity detection signal (analog value) measured by SEN-
SOR HUM&TE in the machine
Temperature detection signal (analog value) measured by
SENSOR HUM&TE in the machine
MOTOR ASSY-DISP 30K ON/OFF control signal
4-11