Built In Siren Alarm In Disarm & Partial Arming; Wireless Siren Alarm; Indication Of System Problems When Arming - jablotron JA60K Installation Manual

Table of Contents

Advertisement

7.2.17. Arming and disarming chirp sounds
The control panel confirms arming with a beep and disarming with two beeps (3 beeps after disarming indicates user in-
formation on the LED display). These sounds can also be generated more loudly with the built in siren.
options:
3 6 1
3 6 0
Factory default setting: siren chirps disabled
Note: setting of chirp sounds is valid even if the siren is disabled for alarms with parameter 320. Partial arming is always
silent, if sequence 340 is selected. Chirp sounds can also be generated with the JA60A wireless siren (self-contained set-
ting in the wireless siren).
7.2.18. Built in siren alarm in Disarm & Partial arming
The built in siren can be disabled for alarms during the Disarm & Partial arming of the control panel (while somebody is
indoors). If the built in siren is completely disabled for alarms with parameter 320, this setting is moot.
options:
3 7 1
3 7 0
Factory default setting: enabled

7.2.19. Wireless siren alarm

The wireless siren alarm function can be disabled with this parameter. This setting will have no influence on the outdoor
siren chirp sounds function if enabled in the siren .
options:
3 8 1
3 8 0
Factory default setting: siren enabled

7.2.20. Indication of system problems when arming

The system regularly checks the conditions of all items (detectors, keypads etc.). This setting ensures that the user will be
warned with 4 rapid beeps after arming, if any component of the system is not ready for arming. Cause of the problem (for
example permanently triggered detector, lost communication etc.) will remain displayed on the control panel. If the user
ignores this warning, the system will arm after exit delay, then an alarm will be triggered and finally the problematic item
will be bypassed for this arming period. After disarming in such a mode, three beeps will be generated as well.
When the indication is not selected, the problematic item will be bypassed when arming with neither warning nor alarm.
If a permanently activated detector is deactivated during arming (for example your main door is not closed), the bypass of
this detector will be canceled automatically and the detector will be ready to trigger an alarm after it is activated (if you
close the door after the system is armed).
options:
3 9 1
3 9 0
Factory default setting: warning disabled
Alarm system JA-60 "COMFORT"
siren chirps enabled
siren chirps disabled
alarm in disarm & partial arming enabled
alarm in disarm & partial arming disabled
siren enabled
siren disabled
warning enabled
warning disabled
-
14 -
sequence: 3 6 x
sequence: 3 7 x
sequence: 3 8 x
sequence: 3 9 x
MDY51306

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ja60x

Table of Contents