12.10. Controlling of a subsystem
A wireless master control panel receives event signals (alarms, tampering, faults, low battery) from a JA-6x subsystem if
enrolled - see 12.1 and 12.11. This will cause the same kind of event on the master control panel and J will be indicated
as the source of the event on the keypad.
The master and slave control panels can be either armed and disarmed as two independent systems or the slave system
can follow the arming and disarming of the master. If the master should rule arming of the slave subsystem, make the
following settings:
a. enroll a subsystem to the master's J position,
b. place the master panel into the programming mode (P is indicated),
c. enter the enrolling mode in the sub-control panel (pressing key 1 while in the programming mode)
d. enter 290 on the master control panel – this way the master will be enrolled to the slave sub-control panel as a
wireless controller (to the first free position of c1 to c8)
e. turn both systems to standby mode and check that the subsystem will be armed (in 2 seconds) after arming of
the master control panel. Check the same for disarming
Notes:
Master control panel generates wireless commands Arm and Disarm the same way as a remote control RC-11. The control
panel transmits these commands only if it has a subsystem enrolled in its position J.
The Arm command is generated when the master control panel is completely armed and also at the end of an alarm while
the system remains completely armed (automatic alarm timeout). The Disarm command is generated when the master
control panel is disarmed, when it is partly armed (home arming or one section arming if it is split) and also in the end of an
alarm while the system is disarmed (manual termination of the alarm).
The subsystem can also be operated by its other controllers (remote controls, keypads) if there are any. For better
understanding you can simply imagine, that the master control panel is just another remote control.
Controlling of the subsystem by the master control panel can be disabled by erasing the corresponding cN position in
the sub-control panel. For example if the master control panel was enrolled to position c3, scroll to this position in the
enrolling mode and holding key 2 will erase the master control panel as a controller.
12.11. Enrollment of the control panel to a UC-2xx or to a master control panel sequence: 2 9 9
The control panel can send wireless data to output modules UC–216, UC–222 and UC-260 (see section 24.). It can also
work as a subsystem of another JA-65 or JA-60 control panel.
Enter the enrolling mode of the UC receiving device and then enter 299 and the control panel will transmit the enrollment
signal.
If you want to enroll a subsystem to your control panel, enter the enrolling mode on the MASTER control panel (see
12.1.) and then enter sequence 299 in the programming mode of the sub control panel.
If the system is split the sub control panel enrolls to the common shared section.

12.12 No code requested for

If this parameter is enabled no code is requested for functions F1, F2, F3, F4, F8 and F9 (or the
the keypad). When this parameter is disabled these functions (keys) can be used only when followed by a code (Master
or User) – see the following table:
Factory default setting: no code requested
Note: this feature is also selectable on the JA-60D wireless keypad and it is
independent from the control panel setting.
12.13. Partial (Home) arming with
In partial arming, the control panel reacts only to detectors addressed to section A (see 12.2 and 12.23) and it ignores the
triggering of detectors in section B or C (except smoke and gas detectors). Partial arming can be disabled with this sequence.
options:
3 1 1
3 1 0
Factory default setting: partial arming enabled
Alarm system JA-65 MAESTRO
,
,
partial arming enabled
partial arming disabled
(F1, F2, F3), F4, F8 & F9
,
(F2) (non split control panel)
- 13 -
function / setting
arming
partial arming
door opening
memory reading
Appliance control
message listening
„code" = Master or User
sequence: 2 9 0
sequence: 3 0 x
,
,
keys on
300
301
„code"
F 1
F 2 „code"
F 2
F 3 „code"
F 3
F 4 „code"
F 4
F 8 „code" 0
F 80
F 8 „code" 1
F 81
F 9 „code"
F 9
sequence: 3 1 x
MFM51210