Menu command
Description
Output data set
---
Settings
Sets data to output to selected data
number.
Rename
Changes the name of the selected data
number.
Copy
Copies the contents registered in the
selected data number to another data
number.
Delete
Clears the content of the selected data
number.
Output character set ---
String output on/
Selects whether the scanned string is
off
output by Ethernet.
Partial output on/
Selects whether an output range is spec-
off
ified.
Output string
Sets the starting and ending digits of out-
setup
put.
NG String out-
Selects whether an NG scan result is
put on/off
output by Ethernet.
Output form
---
Output form
Selects the format of the data to be
output.
When
Digits
Sets the digits of the integer part,
output
of inte-
including the sign. However, + is not out-
format
ger
put for positive numbers.
Example: Setting 4-digit data: −5963 is
is
output as −999.
ASCII
Digits
Sets the output digits for the decimal
of deci-
part. If it is set to 0, the decimal part is
mal
rounded off before the data is output.
Minus
Selects what to display as the sign when
the number is negative.
0 sup-
Selects the method to adjust unused dig-
press
its on the left in output data.
ON: Zeros are inserted for unused digits.
OFF: Spaces are inserted for unused
digits.
Example:
The following examples are for when five
integer digits and three decimal digits are
set and the data is 100.000.
ON: 00100.000
OFF: _100.000 (The underscore indi-
cates a space.)
When
Field
Selects the separator to use between
Output
separa-
output data.
Format
tor
Is
Record
Selects the separator to use between
ASCII
separa-
sets of output data.
tor
When
Deci-
Selects the numerical expression for
output
mal
binary output.
format
output
Fixed-decimal-point data is multiplies by
is
form
1,000 and the result is output.
Binary
I/O monitor
Used to check I/O connections.
FQ-CR2 User's Manual
Setting range
Data 0 to data 31
Text strings of the set inspection items.
The name can be changed to a name
with up to 15 alphanumeric characters.
---
---
Inspection Items 0 to 31
ON, OFF (default)
ON, OFF (default)
1 to 1024
ON, OFF (default)
---
ASCII (default) or Binary
1 to 10 (Default: 6)
0 to 4 (default: 4)
− (Default) or 8
ON or OFF (default)
None (default), comma, tab, space, CR,
LF, or CR+LF
None (default), comma, tab, space, CR,
LF, or CR+LF
Floating-point decimal or fixed decimal
(default)
---
Data
Refer-
ence
Scene
p. 120
Scene
---
---
---
Scene
Scene
Scene
Scene
Scene
---
Scene
p. 122
Scene
Scene
Scene
Scene
Scene
p. 130
Scene
p. 122
Scene
p. 123
---
p. 75
161
Menu Tables