Executes One Measurement - Omron FQ-CR2 User Manual

Fixed mount 2d code reader
Hide thumbs Also See for FQ-CR2:
Table of Contents

Advertisement

Measurement Control and Measurement Acquisition Commands
● MEASURE or M or GL/GC/SC
Execute Measurement
This command executes one measurement.
If Ethernet output is not set, only the measurement is performed.
If Ethernet output is set, the measurement is performed and the result is returned as response data.
<Command Format>
M
E
A
S
U
<Response Format>
When the Command Is Processed Normally
O
K
CR
Measurement
CR
result
Delimiter
When the Command Is Not Processed Normally
E
R
CR
Delimiter
<Parameter Descriptions>
Measurement result
The measurement result is output as the response when Ethernet output is set.
The measurement result is not output when Ethernet output is not set.
FQ-CR2 User's Manual
or
R
E
CR
Delimiter
Reference: Setting the Data to Output via Ethernet (p. 120)
or
M
CR
G
Delimiter
Outputting/Controlling with Ethernet
L
CR
Delimiter
129