External_Reference_Data_Nu; External_Reference_Data_Nu Mber; Acquires The Inspection Item - Omron FQ-CR2 User Manual

Fixed mount 2d code reader
Hide thumbs Also See for FQ-CR2:
Table of Contents

Advertisement

● ITEMDATA or ID
Acquire Inspection Item Data
This command acquires the parameters and measurement values of the specified inspection item.
<Command Format>
Command
I
T
E
M
D
or
I
D
Inspection item
Command
number
(2 digits max.)
Space
Space
(0×20)
(0×20)
<Response Format>
When the Command Is Processed Normally
Acquired
CR
value
O
K
CR
Delimiter
When the Command Is Not Processed Normally
E
R
CR
Delimiter
<Parameter Descriptions>
Inspection item number
External reference data
number
Acquired value
FQ-CR2 User's Manual
Inspection item number
(2 digits max.)
A
T
A
Space
(0×20)
CR
Delimiter
External reference
data number
(3 digits max.)
Specifies the inspection item number. (0 to 31)
Specifies the external reference data number. (0 to 999)
Refer to 10-2 External Reference Parameters (p. 168) for details.
Returns the data for the specified inspection item.
Refer to 10-2 External Reference Parameters (p. 168) for details.
External reference
data number
(3 digits max.)
CR
Delimiter
Space
(0×20)
Outputting/Controlling with Ethernet