Starts Continuous Measure - Omron FQ-CR2 User Manual

Fixed mount 2d code reader
Hide thumbs Also See for FQ-CR2:
Table of Contents

Advertisement

Start Continuous Measurements
This command starts continuous measurements.
If Ethernet output is not set, only continuous measurement is performed.
If Ethernet output is set, continuous measurement is performed and the results corresponding to the number of
measurements made are returned as response data.
<Command Format>
M
E
A
S
<Response Format>
When the Command Is Processed Normally
O
K
CR
Measure-
CR
ment result
Data returned for the
Measure-
number of continu-
CR
ment result
ous measurements
made.
Measure-
CR
ment result
Delimiter
When the Command Is Not Processed Normally
E
R
CR
Delimiter
<Parameter Descriptions>
Measurement result
130
Outputting/Controlling with Ethernet
U
R
E
/
C
Delimiter
The measurement results corresponding to the number of measurements made are out-
put when Ethernet output is set.
The measurement result is not output when Ethernet output is not set.
Reference: Setting the Data to Output via Ethernet (p. 120)
or
CR
M
/
or
C
CR
G
C
Delimiter
Delimiter
FQ-CR2 User's Manual
CR