Quick Guide For Operation Of Ml Panel - Kemppi Promig 530 Operation Instructions Manual

Table of Contents

Advertisement

5. Store them into memory by turning the SAVE switch. Note! When necessary you can check
the values stored on the memory channel by turning the SELECTO mode switch on position
ON, then the displays show values which are in memory of the channel in question.
6. Turn the SELECTO mode switch on position ON, then channels are ready for welding. Note!
You cannot store into memory MMA welding values and MIG two-sequence/four-sequence
selection
MMA welding
1
2
6
1. Select MMA welding with selecting switch for method
2. Select the control mode: local control, remote control or gun control
3. Adjust required MMA current. Values are shown in displays
4. Set welding dynamics on position zero or on required position
5. Weld and adjust MMA current when needed

1.2.4. Quick guide for operation of ML panel

MIG welding with independent adjustments for wire feed and voltage
1
2
4
6
1. Select with selecting switch for method MIG two-sequence procedure or MIG four-sequence
procedure
2. Select with SYNERGIC mode switch the position MIG
3. Select the control mode: local control, remote control or gun control
4. Adjust required set values for wire feed speed and voltage. Values are shown in displays
5. Set welding dynamics at zero position or at required position
6. Weld and adjust wire feed speed and voltage when needed
 – Promig 530 / 061
4
2
5
3
© kemPPi oy