Programming of memory channel:
1. Select channel 1...5
2. Set SELECTO mode switch on position SET.
3. Find by welding correct values for wire feed speed, voltage and welding dynamics.
4. Store them by using the SAVE switch.
Note! If you want to you can check data which you have stored on memory channel by setting
SELECTO mode switch on position ON, when displays show values which are in memory
of the channel in question.
5. Set SELECTO mode switch on position ON and channels are in welding use.
From SELECTO operations go to normal MIG/MAG welding by setting the SELECTO mode
switch on position OFF.

3.2. mL CONTROL PANEL 6263502

S31
S34
S35
P31
R31
P32
MIG basic operations
Welding method selection (S31): MIG two-sequence procedure, MIG four-sequence procedure,
MMA
Control mode selection (S32): local, remote, gun
Local controls: wire feed speed/welding power/MMA current (R31), welding voltage (R32)
Controls for MIG and MMA welding dynamics (R33)
Digital displays: wire feed speed (P31), current (P32), voltage (P33)
Retrieval of last used welding values (S33)
0 – Promig 530 / 061
S36
R33
S33
R32
P33
S32
© kemPPi oy