THRUSH S2R – G10 Maintenance Manual page 166

Single cockpit and dual cockpit
Table of Contents

Advertisement

AIRCRAFT MAINTENANCE MANUAL
INSTRUMENT TROUBLE SHOOTING CHART, Table 8-1, Page 5
HOPPER QUANTITY SYSTEM (OPTIONAL EQUIPMENT)
PROBLEM
No indication on
indicator
No indication
and resistance
checked good
No indication
and resistance
checked good
Table 8-2: Hopper Level Sensor Calibration Chart
BLUE
BLACK
BROWN
APPROXIMATE RESISTANCE WITH FLOAT IN CENTER OF TUBE
1.
BLACK
BLUE
2.
BLACK
BROWN
3.
BROWN
BLUE
4.
BLACK
BLUE
Effective: 03/26/2010
THRUSH AIRCRAFT, INC – MODEL S2R-G10
PROBABLE CAUSE
Bad sensing element
Bad indicator
Bad FA-A control
LEVEL SENSING UNIT
3000 – 5000
2000 – 3000
SMALLER OR EQUAL TO BLACK/BROWN PLUS
RESISTANCE BETWEEN BROWN/BLUE
Disconnect wires and check resistance.
Refer to Table 8-2.
Resistance check bad. Replace
element (non-repairable).
Check power and ground connections.
Observe meter on FA-A control unit. If
meter works with movement of ball,
indicator or wires to indicator are bad.
Check wiring. Wiring OK, replace FA-A
control. Pins 5, 8, 11 and 15 are power
pins on FA-A unit. Pin 15 is attached to
1A C/B. Pins 8 and 11 are jumped to
pin 15. Pin 5 goes to + on rear of tank
quantity gauge. Grounds are located on
pins 4 and 16. Pin 4 is connected to
ground on rear of tank quantity gauge.
Pin 16 is chassis ground.
WIRES COMING FROM TUBE
2000
REMEDY
OHMS
OHMS
OHMS