Appendix E: Canadian Versions of SLC Devices

UL-listed SLC Device
ULC-listed SLC Device Description
Detectors
AD350/AD355
AD350A/AD355A
CP350/CP355
CP350A/CP-355A
SD350/SD355
SD350A/SD355A
SD350T/SD355T
SD350TA/SD355TA
H350/H355
H350A/H355A
H350R/H355R
H350RA/H355RA
H355HT
H355HTA
DNR
DNRA
Bases
B210LP
B210LPA
B501
B501A
B501BH, B501BHT
B501BHA, B501BHTA
B501BH-2, B501BHT-2
N/A
B224RB
B224RBA
B224BI
B224BIA
B200SR
B200SRA
B200SR-LF
N/A
Monitor and Zone Interface Modules
MMF-300
MMF-300A
MMF-302
MMF-302A
MDF-300
MDF-300A
MMF-301
MMF-301A
BG-12LX
BG-12LX
Control Modules
CMF-300
CMF-300A
CRF-300
CRF-300A
82
Intelligent detector that combines a photoelectric sensing chamber and fixed
temperature heat detection (135°F/57.2°C).
Addressable, intelligent smoke detector that incorporates an ionization sensing
chamber. Designed to provide open area protection.
Addressable intelligent smoke detector that uses a photoelectric sensing
chamber. Listed for use in ducts. Designed to provide open area protection.
Adds thermal sensors that will alarm at a fixed temperature of 135°F (57°C).
Intelligent thermistor sensing circuit for fast response. Designed to provide
open area protection with 50 foot spacing capability. A fixed temperature
sensor with 135°F fixed temperature alarm.
Incorporates a thermal rate of rise of 15°F (9.4°C).
High temperature sensor with 190°F (87.8°C) fixed temperature alarm.
Photoelectric Duct Detector, Low-flow. Requires SD350(A)/SD355(A) detector.
Standard U.S. Low-Profile base (6", 15.24 cm).
Standard European flangeless base (4", 10.16 cm).
Sounder base, includes Sounder base with temporal sounder (UL 8th Edition).
Sounder base, includes Sounder base with temporal sounder (UL 9th Edition).
Low Profile Intelligent relay base.
Low Profile Intelligent isolator base.
Intelligent sounder base, temporal or steady.
Intelligent sounder base for low frequency applications
Used for normally open contact alarm initiating devices, such as manual pull
stations, four-wire smoke detectors, heat detectors, waterflow, and supervisory
devices.
Used to interface with two-wire smoke detectors in addition to normally open
contacts.
Two independent 2-wire Initiating Device Circuits (IDCs) at two separate,
consecutive addresses. Wire supervised IDCs as NFPA Style B (Class B) or
Style D (Class A) circuits. The modules come with a thermoplastic cover for
mounting to a 4-inch (10.16 cm) square mounting box.
Functionally similar to the MMF-300 Monitor Module, but offered in a smaller
package for mounting directly in the electrical box of the device being
monitored. (Class B input circuit only.)
An addressable manual pull station with key-lock reset feature. The
addressable module is housed within the pull station.
Control Module, NAC: Addressable Control Module used as Notification
Appliance Circuits (NACs) to power and supervise compatible, UL-listed
notification appliances. Wired supervised NACs as NFPA Style Y (Class B) or
Style Z (Class A). The modules come with a thermoplastic cover for mounting
to a 4-inch (10.16 cm) square mounting box.
Relay Control Module is similar to the CMF-300(A) except used as a Form-C
control relay module.
FireLite SLC Wiring Manual — P/N 51309:P4 9/17/2014