CP350 - An addressable ionization smoke detector which measures the level of combustion
products in its chamber using the 'ionization principle'.
CP355 - An addressable ionization smoke detector which measures the level of combustion
products in its chamber using the 'ionization principle'.
D350P - An addressable photoelectric duct detector. The D350RP includes an alarm relay. Air
velocity rating is 500 to 4,000 feet per minute.
D350PL -An addressable low flow photoelectric duct detector (D350PLA for Canada). The
D350RPL includes an alarm relay (D350RPLA for Canada). Low Flow refers to the air velocity
rating of 100 to 4,000 feet per minute (0.5 to 20.32 m/sec).
D355PL - An addressable non-relay photoelectric low flow smoke detector. Low Flow refers to
the air velocity rating of 100 to 4,000 feet per minute (0.5 to 20.32 m/sec).
1
H350
- An addressable detector using a thermistor sensing circuit for fast response. H350R
incorporates a thermal rate of rise of 15°F (9.4°C)/minute.
1
H355
- An addressable 135° fixed temperature heat detector using a thermistor sensing circuit for
fast response. H355R incorporates a thermal rate of rise of 15° F (9.4° C)/minute.
H355HT
for fast response.
SD350 - An addressable photoelectric smoke detector which provides smoke sensing utilizing
optical sense technology. The SD350T includes a 135° F fixed thermal sensor.
SD355 - An addressable photoelectric smoke detector which provides smoke sensing utilizing
optical sense technology. The SD355T includes a 135° F fixed thermal sensor. The SD355R is a
low profile, intelligent, photoelectric sensor that is remote test capable.
BEAM355 - An addressable long range projected beam smoke detector designed to provide open
area protection. The BEAM355S has an integral sensitivity test feature that consists of a test filter
attached to a servomotor inside the detector optics.
DNR(W) - Innovair Flex, intelligent, non-relay, low flow, photoelectric duct detector housing.
This requires the SD355R photoelectric smoke detector. Accomodates the installation of the CRF-
300 relay module. The DNRW is a watertight housing.
1.4.7 Manual Pull Station
The BG-12LX is a dual-action pull station that, when activated, provides an addressable
identification and its location to the control panel. An addressable monitor module is mounted
inside the pull station to facilitate servicing and replacement.
1.4.8 Wireless Gateway
W-GATE: The Wireless Gateway acts as a bridge between a group of wireless fire devices and a
LiteSpeed SLC loop on the MS-9200UDLS. It is powered by the SLC loop or by a regulated,
external 24VDC UL listed power supply. Available wireless devices include a photo detector, a
photo/heat detector, a fixed-temperature heat detector, a rate-of-rise heat detector, and a monitor
module. For details about wireless devices, system setup, and operation, see the SWIFT™ Smart
Wireless Integrated Fire Technology Instruction Manual.
NOTE: The W-GATE, as part of the wireless network, has been tested for compliance with the
Federal Communications Commission (FCC) requirements of the United States Government. It
has not been evaluated for use outside the USA. Use of this system outside the USA is subject to
local laws and rules to which this product may not conform. It is the sole responsibility of the user
to determine if this product may be legally used outside the USA.
1. Addressable Heat Detectors are not compatible with the MS-9200(E).
12
1
- An addressable 190° fixed temperature heat detector using a thermistor sensing circuit
FireLite SLC Wiring Manual — P/N 51309:P4 9/17/2014
Devices

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents