Process Timer Values - ESAB Precision Plasmarc Installation, Operation And Maintenance Manual For Residential Installation

With electronic flow control
Hide thumbs Also See for Precision Plasmarc:
Table of Contents

Advertisement

SECTION 6
6.12.2 Process Timer Values For Vision Cutting Record File PARAM.CUT
Vision Interpretation Data File DEF.TEC
Plasma Preflow Time
Line Purge Time
Plasma Firing Time
Plasma Pierce Time
Plasma Ahc Delay
Plasma Arc Delay
Master Up
Analog Channel Disable
Line Fill Time
Plasma Postflow
Line Vent Time / Flow Control Vent Time
TIMERS
PARAM.CUT
V = Hidden Flag Enabled
0.6
0.6
0.6
0.6
1.0
1.0
1.0
1.0
6.0
6.0
6.0
6.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.3
0.3
0.3
0.3
2.0
2.0
2.0
2.0
600.0
600.0
600.0
600.0
600.0
600.0
600.0
600.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
2.0
2.0
2.0
2.0
6-22
TROUBLESHOOTING
0.5
0.5
50.0
50.0
0.5
0.5
50.0
50.0
1.0
1.0
1.0
1.0
50.0
50.0
50.0
50.0
4.0
4.0
6.0
6.0
4.0
4.0
6.0
6.0
0.0
0.0
0.0
0.0
50.0
50.0
50.0
50.0
0.0
0.0
50.0
50.0
0.0
0.0
50.0
50.0
0.0
0.0
0.0
0.0
0.5
0.5
0.5
0.5
0.0
0.0
50.0
50.0
0.0
0.0
50.0
50.0
600.0
600.0
600.0
600.0
5.0
5.0
50.0
50.0
5.0
5.0
50.0
50.0
5.0
5.0
5.0
5.0
50.0
50.0
50.0
50.0
2.0
2.0
50.0
50.0
2.0
2.0
50.0
50.0
DEF .TEC
V V V V
V V V V
V V V V
V V V V
V V V V
V V V V
V V V V
V V V V

Advertisement