SECTION 3
Pilot Arc
Work
Torch
Power Source
600 amp
Bus Fuse
Rating
Label
Serial
Tag
Coolant In from Torch
# 6 Connection
Coolant Out to Torch
# 7 Connection
Remove Access Cover
Pilot Arc
Work
Torch
CNC Control Lead
Flow Control
Lead
CONTROL LEAD
7. Remove panel from rear of console and attach the
pilot-arc, torch and work lead.
8. Connect control lead between the console and the
Electronic Flow Control. Connect coolant lines of
the Power Bundle.
3-9