SECTION 6

6.7 Junction Box Schematic

A
B
C
D
E
TO FLOW
F
CONTROL
G
J2
H
J
K
L
M
N
I
NEG
CABLE
CONNECTIONS
TO CONSOLE
PILOT
ARC
WORK
J1
GND1
T3
H2
X2
H1
X1
PCB1
1
3
GND1
SCHEMATIC DIAGRAM
PLASMA-1
SOLENOID COMMON
PLASMA-2
SHIELD GAS 1
SHIELD GAS 2
2
SG1
1
2
.002 uf
2500pf
C1
C2
10KV
15KV
1
X1 X2
X3
T1
X2
X1
X3
2
T2
6-9
TROUBLESHOOTING
J2
BLU
2
6
5
5
6
3
PG-1
7
8
1
4
3
1
ORG
4
2
SG-1
9
MANIFOLD
EFC A/M
NEG
TORCH
CONNECTIONS
PILOT
ARC
YEL
PG-2
BLK
SG-2