Use the Covermeter to locate and measure the minimum area of cover within each grid cell, or
the cover to the reinforcement bar nearest to each grid-point, depending upon your survey
procedures.
•
Store the results in a grid batch corresponding to the grid of squares (press [ ] to enter a
reading while the batch is open).
•
If required, create a separate batch of the same name configured for half-cell and store
corresponding half-cell potential measurements for each location. This allows the batches to
be grouped for production of reports which combine cover and half-cell readings using
®
CoverMaster
software - see "CoverMaster software" on page 53.
14.3 What does a batch contain?
Each batch stores three types of information:
•
header fields
•
readings
•
statistics
Symbol
Symbol meaning
Batch name
Batch type (Cover or half-cell)
Batch format (
nx
Number of columns (nx)
ny
Number of rows (ny)
n
Number of readings taken (n)
Site
Location
Area
Grid spacing (size of each grid square)
Bar size/diameter
Batch creation date/time
Batch update date/time
Low limit
High limit
(information entered by the user - see below)
(entered automatically by the 331 as you are taking measurements)
(entered automatically by the 331 as you are taking measurements)
Table 2: Batch contents
a
or
)
B
/D
ATCHING
ATA LOGGING
Typical contents
001-1 or Survey-01
10 (only displayed
for
batches)
10 (only displayed
for
batches)
96
Humber Bridge
North Pier
AA/123/4-001
500 mm
18 mm
09:30 17/01/06
14:15 19/01/06
20 mm
35 mm
R
Entered by
User
331