EASURING DEPTH OF COVER

6.4 Accuracy

The reading of cover will only be accurate if all the following conditions are satisfied:
The instrument has been zeroed.
The search head is over the centre-line of the bar.
The search head is parallel to the bar.
The search head is not over, or near, any other bars which might affect the reading
The manually entered bar size has been confirmed as being accurate by comparing with the
autosize estimate.
If the reinforcement bar is too deep to measure successfully (over-range), the depth of cover will be
displayed as infinite (Figure 14).
u.
If reinforcement bars are too close together to measure with the standard search head, try using the narrow
pitch search head. See "Accessories" on page 64 for ordering details.