ETTING STARTED

3.10 Using the earphone

To use the earphone, plug the connector into the 3.5 mm socket marked
on the front of the
Covermeter. Replacement earphones are available as an optional accessory - see "Accessories"
on page 64.

3.11 Zeroing the Covermeter

This action is requested by the Covermeter whenever it is switched on with a search head attached,
when a cover batch is opened, on entering orthogonal SIZE mode, and periodically thereafter (at
least once every 10 minutes). The user can choose to zero the instrument at any time.
If zeroing is required, the cover display is blanked, the user is prompted, and no further readings
can be entered until zeroing is completed.
To zero the Covermeter, hold the search head in the air well away from any metal and press the
ZERO softkey. Zeroing is complete when the ZERO softkey indicator stops flashing. Sometimes
more than one press of the ZERO softkey will be required; this is quite normal.
When a half-cell probe is attached to the instrument, zeroing is not required.