Use the CoverMaster
Page
Designer...
Figure 31. Produce professional reports
18.3 Connecting the data transfer cable
1. Plug the 9-pin female D-type connector on one end of the data transfer cable into the COM
port on the PC (an RS232 to USB transfer cable is available which allows you to connect your
Covermeter to a USB port on your computer - see "Accessories" on page 70 for ordering
details).
2. Plug the 5-pin connector on the other end of the data transfer cable into the RS232 connector
at the rear of the Covermeter located under the access cover - see "Computer interface" on
page 11.
3. Switch on the Covermeter and ensure that the Reading Screen is displayed.

19 SEARCH HEADS

Four types of search head are available for your Covermeter; Standard, Narrow Pitch, Deep Cover
and Borehole Probe. To order any of these search heads see "Accessories" on page 64.
ak. The illustrations in Figure 30 and Figure 31 show a grid batch. Grid batches are only available on Model 'T'
Covermeters. Model 'SH' Covermeters can save up to 10 linear batches.
...to create your own reports
Batch Name:
Jnt 15 NE 1
Inspection Date:
11/11/2004 11:10:27
Comments:
Surface cracking apparent
Customer Name:
Highways Department
Measured Cover in mm
A
B
C
D
E
F
G
H
I
J
K
L
M
N
O
P
Q
R
S
T
U
V
W
1
2
3
4
5
Batch Name:
Jnt 15 NE 1
Inspection Date:
Comments:
Surface cracking apparent
Customer Name:
6
7
Measured Cover in mm
8
105
9
100
95
10
90
85
80
75
70
65
10
16
23
29
36
42
49
55
61
68
74
81
87
94
100
60
55
Batch Name:
50
Comments:
42
45
36
40
31
Measured Cover in mm
35
23
30
22
21
Site:
M25 Expressway
Rows:
25
Area:
NE Section 1
Columns:
20
Engineer:
John Smith
Readings:
15
Customer:
Highways Department
Creation Date:
11/11/2004 11:10:27
1
10
1
Note:
Surface cracking apparent
Update Date:
11/11/2004 11:10:27
5
2
Location:
Exit 15
Batch Format:
0
Bar Series:
Metric
High Limit:
-1
5
11
17
23
29
35
41
3
Bar Size:
5.5 mm
Low Limit:
Grid Spacing:
4
5
Mean Average:
Standard Deviation:
6
Max:
Min:
7
Range:
8
Readings Below Low Limit:
Site:
M25 Expressway
Readings Above High Limit:
Area:
NE Section 1
9
Percent Below Low Limit:
Engineer:
John Smith
Percent Above High Limit:
10
Customer:
Highways Department
Note:
Surface cracking apparent
Location:
Exit 15
Bar Series:
Metric
Bar Size:
5.5 mm
10
1
Printed on 29/03/2005
Elcometer CoverMaster Software
2
www.elcometer.com
3
4
5
6
7
8
9
10
Printed on 29/03/2005
Elcometer CoverMaster Software
www.elcometer.com
Site:
Area:
Engineer:
Customer:
Note:
Location:
Bar Series:
Bar Size:
Printed on 29/03/2005
Elcometer CoverMaster Software
www.elcometer.com
ak
direct from CoverMaster
S
EARCH HEADS
X
0.20
0.40
0.60
0.80
11/11/2004 11:10:27
1.00
Highways Department
1.20
1.40
1.60
1.80
2.00
69
106
Jnt 15 NE 1
Inspection Date:
11/11/2004 11:10:27
Surface cracking apparent
Customer Name:
Highways Department
34
10
24
A
B
C
D
E
F
G
H
I
J
K
L
M
N
O
P
Q
R
S
T
U
V
W
X
236
1
0.20
Grid
0.40
85 mm
47
53
59
65
71
77
83
89
95
mm
25 mm
0.60
200 mm
High Limit
Low Limit
0.80
35 mm
1.00
14 mm
56 mm
1.20
5 mm
1.40
51 mm
68
Rows:
10
1.60
0
Columns:
24
28.81%
1.80
Readings:
236
0.00%
Creation Date:
11/11/2004 11:10:27
2.00
Update Date:
11/11/2004 11:10:27
Batch Format:
Grid
High Limit:
85 mm
Low Limit:
25 mm
Grid Spacing:
200 mm
16
23
29
36
42
49
55
61
68
74
81
87
94
100
106
Mean Average:
35 mm
A
Standard Deviation:
B
C
D
E
F
G
H
I
J
K
L
14 mm
M
N
O
P
Q
R
S
T
U
V
W
X
Max:
56 mm
30
42
12
33
26
18
24
33
38
44
50
47
46
47
48
50
46
55
47
42
43
44
43
43
Min:
5 mm
0.20
41
Range:
42
33
19
18
16
26
24
37
41
49
45
51 mm
45
45
49
55
48
50
50
42
44
46
36
41
Page 1
Readings Below Low Limit:
68
0.40
42
Readings Above High Limit:
43
19
18
17
20
27
14
33
33
48
50
52
50
0
52
47
47
51
50
47
42
43
40
45
0.60
Percent Below Low Limit:
28.81%
43
38
19
16
15
5
15
13
19
15
48
45
55
45
52
55
46
51
51
43
48
46
40
47
Percent Above High Limit:
0.00%
0.80
38
34
18
14
19
12
16
19
12
14
47
47
56
45
51
55
50
52
47
44
47
43
27
33
1.00
32
33
18
19
16
11
14
9
10
11
13
44
46
46
50
53
51
50
41
45
38
39
28
23
1.20
38
23
31
19
23
15
16
16
12
13
14
38
55
45
47
52
52
47
45
42
38
37
25
25
1.40
33
34
26
12
24
18
15
12
11
24
22
44
44
48
55
46
52
47
44
38
34
32
24
26
1.60
26
26
23
24
11
18
12
23
29
37
55
49
49
48
49
39
46
37
35
38
19
18
1.80
29
27
28
27
23
27
22
33
29
46
55
50
49
44
47
39
49
35
36
29
19
11
2.00
Page 1
M25 Expressway
Rows:
10
Mean Average:
35 mm
NE Section 1
Columns:
24
Standard Deviation:
14 mm
John Smith
Readings:
236
Max:
56 mm
Highways Department
Creation Date:
11/11/2004 11:10:27
Min:
5 mm
Surface cracking apparent
Update Date:
11/11/2004 11:10:27
Range:
51 mm
Exit 15
Batch Format:
Grid
Readings Below Low Limit:
Metric
High Limit:
85 mm
Readings Above High Limit:
5.5 mm
Low Limit:
25 mm
Percent Below Low Limit:
28.81%
Grid Spacing:
200 mm
Percent Above High Limit:
0.00%