Upgrading Your Covermeter; Technical Data - Elcometer 331 SH Operating Instructions Manual

Concrete covermeter
Table of Contents

Advertisement

U
C
PGRADING YOUR

25 UPGRADING YOUR COVERMETER

Users of the Elcometer 331 model SH can upgrade their instrument to a model TH.
Upgrading your Covermeter will provide you with the following additional features:
Memory of over 240 000 readings in multiple linear and grid batches
Grid batches as well as linear batches
Date and time stamping of measurements
Plot on the display of the Covermeter a 'map' of the readings in a batch for quick and easy
identification of potential trouble spots in a survey
Upgrading of your Covermeter must be carried out by Elcometer or your local Elcometer supplier.
For more information or to arrange to have your Covermeter upgraded, contact Elcometer, your
Elcometer supplier or visit www.elcometer.com

26 TECHNICAL DATA

am
26.1 Performance
Standard search head
Range:
Accuracy:
Pitch resolution:
Narrow Pitch search head
Range:
Accuracy:
Pitch resolution:
Deep cover search head
Range:
an
Accuracy
:
Pitch resolution:
am. All performance figures have been obtained when using Elcometer reference rebars of standard diameter at
room temperature.
an. Accuracy figures for the deep cover search head are obtained once the operating temperature has
stabilised (after 10 minutes continuous use of the search head).
62
R
OVERMETER
40 mm (1.6") bar:
8 mm (0.3") bar:
up to 65 mm (2.6") depth:
over 70 mm (2.8") depth:
16 mm (#5) diameter bar at 50 mm (2") depth of cover;
pitch ≥ 75 mm (3")
40 mm (1.6") bar:
8 mm (0.3") bar:
up to 45 mm (1.75") depth:
over 50 mm (2") depth:
10 mm (#3) diameter bar at 30 mm (1.2") depth of cover;
pitch ≥ 55 mm (2.15")
40 mm (1.6") bar:
8 mm (0.3") bar:
up to 65 mm (2.6") depth:
over 70 mm (2.8") depth:
16 mm (#5) diameter bar at 100 mm (4") depth of cover;
pitch ≥ 125 mm (5")
17 mm to 100 mm (0.65" to 4")
9 mm to 75 mm (0.35" to 3")
±2 mm (0.1")
±3%
9 mm to 75 mm (0.35" to 3")
5 mm to 55 mm (0.2" to 2.2")
±1 mm (0.05")
±2 mm (0.1")
50 mm to 200 mm (2" to 8")
25 mm to 150 mm (1" to 6")
±2 mm (0.1")
±3%

Advertisement

Table of Contents
loading

This manual is also suitable for:

331 th

Table of Contents