B0048991 / Rev. 1.3
The ENTER key leads to the following menu item:
system param. 13
EC: 24-32mS/m
Fig. 67: Setting the conductivity range fort he diagnosis
Here the conductivity range for the diagnosis is set.
Extra: = slightly magnetical NF material
FE = magnetical steel
For NF material the conductivity range is shown.
With the ENTER key and UP/ DOWN keys all ranges can be selected.
The ENTER key will exit the section.
The UP key leads to the following menu item:
system param. 13
DB: <4.00 mm
Fig. 68: Setting the thickness range for the diagnosis
Here the thickness range for the diagnosis is set.
With the ENTER key and UP/ DOWN keys all ranges can be selected.
The ENTER key will exit the section.
The UP key leads to the following menu item:
system param. 13
AD:2048 D:1.22mm
Fig. 69: Indicating the thickness calculated from the characteristic curve
Here the value of the analog-digital converter and the thickness (calculated from the characteristic
curve) are shown (without Teach-In correction). For 2PW units the values for both sensors will be
shown.
The UP key leads to the following menu item:
system param. 13
F=250Hz
Fig. 70: Indicating the frequency and gain
Here the used frequency and gain is shown.
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
Double Sheet Detector R1000 series UDK20
V=157
Manual
Start-up
95