Roland udk20 Manual page 92

Double sheet detector
Hide thumbs Also See for udk20:
Table of Contents

Advertisement

Start-up
System parameter 7: Specifying the Teach-In limits for FE.
system param.
T-limit:66%/125%
Fig. 56: Setting Teach-In limit
Possible choices:
66% / 125 % (default setting)
33% / 142 %
During Teach-In of FE material the deviation of the measured thickness from the nominal thickness
is monitored. Certain ferro-magnetic materials show a larger deviation than usual. In those cases
the 33%/142% setting instead of the default 66%/125% setting is useful. Both values represent the
permitted relative range from measured to nominal thickness. If the measuring value is not within
this range, the Teach-In cannot be performed and will be aborted with an error message.
System parameter 8: Deleting all measuring programs.
system param.
CLR param.:
Fig. 57: Deleting of measuring programs
System parameter 9: Switching the password function on / off.
system param.
password:
Fig. 58: Switching the password on / off
92
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
Double Sheet Detector R1000 series UDK20
7
8
no
Attention
The deletion cannot be undone.
9
yes
Attention
If no password is activated, then all parameters can be accessed
at any time. We recommend this only during starting-up the
system. For daily operation the password function should be
activated.