Double sheet detector
Hide thumbs Also See for udk20:
Table of Contents

Advertisement

Electrical installation
Version B or C with opto coupler outputs
PLC
external power supply
Central machine ground
62
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
Double Sheet Detector R1000 series UDK20
Meas menue select.
Measurement Start
Bit 0
(Teach-In)
Bit 1
(Zero adjust)
Bit 2
Bit 3
System test
Bit 4
Bit 5
Bit 6
Bit 7
PLC/COM
+24 VDC / PLC
Enable
2-sheet
1-sheet
0-sheet
Shield LiYCY 15 x 0,25 mm²
+ 24 VDC
min. 1 mm²
0 VDC
min. 1 mm²
min. 1,5 mm²
Attention
The positive supply voltage +24 VDC should not be connected to
machine ground.
Manual
Central
plug
A1
A2
A3
A4
A5
A6
A7
A8
A9
C1
C2
C3
C4
C5
C6
C7
C8
C9
B2
B3
B4
B5
B6
B7
B8
B0048991 / Rev. 1.3
UDK20
8
IN0
5
IN1
6
IN2
7
IN3
38
IN4
37
IN5
36
IN6
35
IN7
4
PLC/COM
9
+
Out 0
-
10
Enable
+
Out 1
12
-
2-sheet
+
Out 2
14
-
1-sheet
+
Out 3
16
-
0-sheet
max. 250 VAC / 1A
17
+ 24 VDC
18
0 VDC
34
IN8