Roland udk20 Manual page 93

Double sheet detector
Hide thumbs Also See for udk20:
Table of Contents

Advertisement

B0048991 / Rev. 1.3
System parameter 10: Deactivating / activating the external calibration
system param. 10
ext. adj.:
Fig. 59: Deactivating / activating the external calibration
Here the external calibration can be deactivated, which is possible via the interface with the signals
"Teach-In 0-sheet" and "Teach-In 1-sheet".
System parameter 11: Setting the output logic (0-sheet, 1-sheet, 2-sheet outputs).
system param. 11
output 0-1-2: 0V
Fig. 60: Setting the output logic
Possible choices:
0 V:
+24 V: The outputs 0-sheet, 1-sheet and 2-sheet are inverted, i.e. the respective signals in
System parameter 12: Equipment diagnostics (Teach-In factors).
system param. 12
diagnost. factor
Fig. 61: Diagnostics factor
The ENTER key leads to the following menu item:
system param. 12
P12 EC:24-32ms/m
Fig. 62: Indicating the investigated conductance
Here the conductivity investigated for this program is shown (here: prog. 12)
Extra: = slightly magnetical NF material
FE = magnetical steel
For NF material the conductivity range is shown.
With the ENTER key and UP/ DOWN keys all programs can be polled / indicated.
The ENTER key will exit the section.
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
Double Sheet Detector R1000 series UDK20
no
As shown in the timing diagrams and the wiring diagrams
the timing diagrams and wiring diagrams must be seen inverted.
Note
The output "Enable" is not affected thereby.
Manual
Start-up
93