B0048991 / Rev. 1.3
5.2.3
Connection of Sensor Switch Box
The connection for the sensor switch box is only present at unit versions UDK20-x-x-S(-FP),
but not at unit versions UDK20-2PW-x-x-S(-FP).
Connection of the sensor to the Sensor-Switch-Box with the cable „SVCPWS-SSBUDK10".
Sensor cable pin
Pin 1
Pin 2
Pin 3
Pin 4
Pin 5
Plug enclosure
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
Double Sheet Detector R1000 series UDK20
1
2
3
4
5
Meaning
Switching-over signal 1
Switching-over signal 2
Control signal
0 VDC
+24 VDC
Cable shield (both-sided)
Manual
white
green
brown
yellow
grey
Colour of wire
Terminal no. of control unit
white
green
brown
yellow
grey
Electrical installation
1
29
2
30
3
31
4
32
5
33
29
30
31
32
33
57