B0048991 / Rev. 1.3
Program parameter 3: Setting the material of the sheet to be measured.
program par.
material: auto
Fig. 36: Setting the material
Possible choices:
•
Auto: During Teach-In the system determines by itself the type of material in front of the
sensor.
•
NF (non-ferrous): Non magnetic material, e.g. aluminium, austenitic stainless steel
•
FE (ferrous): Magnetic material
•
mag. NF (LM): low magnetic material
Program parameter 4: Setting the nominal thickness of the sheet to be measured.
program par.
nominal:
Fig. 37: Setting the nominal thickness
Value range:
•
0.03 mm to 4 mm (.001 inch to 0.157 inch)
Program parameter 5: Setting the percentage threshold of the upper limit value.
program par.
up
150% 1.350mm
Fig. 38: Setting the upper limit
Value range:
•
100% to 150%
At the same time the absolute limit value is displayed.
Program parameter 6: Setting the percentage threshold of the lower limit value.
program par.
low: 50% 0.450mm
Fig. 39: Setting the lower limit
Value range:
•
0% to 99%
At the same time the absolute limit value is displayed.
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
Double Sheet Detector R1000 series UDK20
3
4
0.90mm
5
6
Manual
Start-up
85