APPENDIX A: FLEXANALOG OPERANDS
Address
FlexAnalog name
7722
SRC 3 Demand VA
7728
SRC 4 Demand Ia
7730
SRC 4 Demand Ib
7732
SRC 4 Demand Ic
7734
SRC 4 Demand Watt
7736
SRC 4 Demand var
7738
SRC 4 Demand VA
7744
SRC 5 Demand Ia
7746
SRC 5 Demand Ib
7748
SRC 5 Demand Ic
7750
SRC 5 Demand Watt
7752
SRC 5 Demand var
7754
SRC 5 Demand VA
7760
SRC 6 Demand Ia
7762
SRC 6 Demand Ib
7764
SRC 6 Demand Ic
7766
SRC 6 Demand Watt
7768
SRC 6 Demand var
7770
SRC 6 Demand VA
8692
Brk 3 Arc Amp A
8694
Brk 3 Arc Amp B
8696
Brk 3 Arc Amp C
8698
Brk 3 Op Time A
8699
Brk 3 Op Time B
8700
Brk 3 Op Time C
8701
Brk 3 Op Time
8702
Brk 4 Arc Amp A
8704
Brk 4 Arc Amp B
8706
Brk 4 Arc Amp C
8708
Brk 4 Op Time A
8709
Brk 4 Op Time B
8710
Brk 4 Op Time C
8711
Brk 4 Op Time
9472
Bus 1 Diff A Mag
9474
Bus 1 Diff A Ang
9475
Bus 1 Diff B Mag
9477
Bus 1 Diff B Ang
9478
Bus 1 Diff C Mag
9480
Bus 1 Diff C Ang
9481
Bus 1 Rest A Mag
9483
Bus 1 Rest A Ang
9484
Bus 1 Rest B Mag
9486
Bus 1 Rest B Ang
9487
Bus 1 Rest C Mag
9489
Bus 1 Rest C Ang
9493
Bus Max CT Primary
9504
Bus 2 Diff A Mag
B30 BUS DIFFERENTIAL SYSTEM – INSTRUCTION MANUAL
Units
Description
VA
Source 3 apparent power demand
Amps
Source 4 phase A current demand
Amps
Source 4 phase B current demand
Amps
Source 4 phase C current demand
Watts
Source 4 real power demand
Vars
Source 4 reactive power demand
VA
Source 4 apparent power demand
Amps
Source 5 phase A current demand
Amps
Source 5 phase B current demand
Amps
Source 5 phase C current demand
Watts
Source 5 real power demand
Vars
Source 5 reactive power demand
VA
Source 5 apparent power demand
Amps
Source 6 phase A current demand
Amps
Source 6 phase B current demand
Amps
Source 6 phase C current demand
Watts
Source 6 real power demand
Vars
Source 6 reactive power demand
VA
Source 6 apparent power demand
kA2-cyc
Breaker 3 arcing amp phase A
kA2-cyc
Breaker 3 arcing amp phase B
kA2-cyc
Breaker 3 arcing amp phase C
ms
Breaker 3 operating time phase A
ms
Breaker 3 operating time phase B
ms
Breaker 3 operating time phase C
ms
Breaker 3 operating time
kA2-cyc
Breaker 4 arcing amp phase A
kA2-cyc
Breaker 4 arcing amp phase B
kA2-cyc
Breaker 4 arcing amp phase C
ms
Breaker 4 operating time phase A
ms
Breaker 4 operating time phase B
ms
Breaker 4 operating time phase C
ms
Breaker 4 operating time
Amps
Bus differential current phase A magnitude
Degrees
Bus differential current phase A angle
Amps
Bus differential current phase B magnitude
Degrees
Bus differential current phase B angle
Amps
Bus differential current phase C magnitude
Degrees
Bus differential current phase C angle
Amps
Bus restraint current phase A magnitude
Degrees
Bus restraint current phase A angle
Amps
Bus restraint current phase B magnitude
Degrees
Bus restraint current phase B angle
Amps
Bus restraint current phase C magnitude
Degrees
Bus restraint current phase C angle
Amps
Bus maximum CT primary
Amps
Bus differential IA magnitude