Part No. 920525 Rev A - Wayne 3/VISTA series Service Manual

Blending and non-blending dispensers
Table of Contents

Advertisement

TABLE 8.1 Procedures for UpLoading and Downloading Computer Code Revisions and Templates.
Power down the pump. Connect laptop via cable and RS-232 adapter to J18 on computer
board. Power up pump and then open the Service Terminal Program (STP) on the laptop,
then
96
To upload
code to pc
press ENTER
upload flash program
press ENTER
select the filename
press ENTER
uploading blocks begins
upload complete
Close STP
1. If this process is now interrupted for any reason, the Bootstrap procedure then must be used to download to dispenser.
2. After briefly displaying "Download Complete", the laptop will display "Enter Password" assuming you may want to
proceed to other functions, however, you should Close STP at this time and finish the above procedure and then access
other functions using the IR remote.
June 2001
press
enter
press
enter
press
enter
97
To upload
template to pc
press ENTER
upload template
press ENTER
select the filename
press ENTER
uploading blocks begins
upload complete
Close STP
ENTER
Pass 1 _ _ _ _
ENTER
Pass 2 _ _ _ _
ENTER
Function number
98
To download
code to dispenser
press ENTER
download flash program
press ENTER
enter password (type 42)
press ENTER
browse/select filename
gem_ _.bin
waiting for flash to erase
downloading blocks begins
download complete
2
Close STP
power down pump
remove RS232 & laptop
power up pump
99
To download
template to dispenser
press ENTER
download template
press ENTER
enter password (type 42)
press ENTER
browse/select the proper tem-
plate
1
waiting for flash to erase
downloading blocks begins
download complete
2
Close STP
power down pump
remove RS232 & laptop
jumper S15 Cold Start
power up pump
display reads COLD
remove S15 jumper
program prices, fueling point,
etc., with IR remote

Part No. 920525 Rev A