Part No. 920525 Rev A - Wayne 3/VISTA series Service Manual

Blending and non-blending dispensers
Table of Contents

Advertisement

Sub-function numbers are in the format: .XN where X = the selected configuration parameters and
N = the logical nozzle number 1-8.
.0N
Octane number assignment, 00-99, 00 = None assigned
.1N
Product select button input number assignment, 0-8, 0 = None assigned
.2N
Push-to-Start button input number assignment, 0-8, 0 = None assigned
.3N
Vapor recovery system enabled, 1 = Yes, 2 = No
.4N
Beep annunciator in a series of six beeps on physical nozzle lift, 1 = Yes, 2 = No
F11 - Side B Dispenser Type Configuration Part #2
Sub-function numbers are in the format: .XN where X = the selected configuration parameters and
N = the logical nozzle number 1-8.
.0N
Octane number assignment, 00-99, 00 = None assigned
.1N
Product select button input number assignment, 0-8, 0 = None assigned
.2N
Push-to-Start button input number assignment, 0-8, 0 = None assigned
.3N
Vapor recovery system enabled, 1 = Yes, 2 = No
.4N
Beep annunciator in a series of six beeps on physical nozzle lift, 1 = Yes, 2 = No
F12 - Side A Pump Assignments
Sub-function numbers are in the format: .XN where X = the selected configuration parameters and
N = the logical nozzle number 1-8.
.0N
Primary pump assignment, 0-8, 0 = None assigned
.1N
Secondary pump assignment, 0-8, 0 = None assigned
F13 - Side B Pump Assignments
Sub-function numbers are in the format: .XN where X = the selected configuration parameters and N = the logical
nozzle number 1-8.
.0N
Primary pump assignment, 0-8, 0 = None assigned
.1N
Secondary pump assignment, 0-8, 0 = None assigned
F14 - Dispenser Display Configuration (both sides)
Sub-function numbers are in the format .0X where X = the selected configuration parameters defined as follows:
.00
Number of unit price displays per side, 0-8, 0 = None supported
.01
Display mode after sale paid
1 = Money is actual, volume is actual, unit price is actual
2 = Money is zeros, volume is zeros, unit price is actual
3 = Money is zeros, volume is zeros, unit price is blanks
4 = Money and Volume actual, Unit Price blank
.02
Money display digits right of decimal point, 0-4
.03
Volume display digits right of decimal point, 0-4
.04
Unit Price display digits right of decimal point, 0-4
.05
Flash unit price display when selected after 8 - blanks - 0
1 = No Flash,
2 = Flash until flow
3 = flash always
46

Part No. 920525 Rev A

June 2001

Hide quick links:

Advertisement

Table of Contents
loading