Part No. 920525 Rev A - Wayne 3/VISTA series Service Manual

Blending and non-blending dispensers
Table of Contents

Advertisement

21
Reserved
22
Reserved
23
Reserved
24
Reserved
25
Sale Cannot Start - Zero Unit
Price
26
Sale Cannot Start - No Unit
Price Downloaded
27
Sale Cannot Start - Unit Price
Changed – Function 23.04
28
Sale Cannot Start - Need Preset
Entry – Function 24.01
29
Reserved
30
No Communications with POS
Timeout – Function 23.02
31
Reserved
32
Reserved
33
Sale Aborted Because Stop
Button Pushed
34
Reserved
35
Blend Ratio Out of Tolerance -
Function 7.02
36
Reserved
37
Reserved
38
Reserved
39
Reserved
40
Reserved
41
Reserved
42
Vapor Recovery Motor On
When It Should Be Off
43
Vapor Recovery Motor Off
When It Should Be On
44
Reserved
June 2001
Unit price not set
POS has not set a unit price
Unit price has changed prior to start
of sale
Sale requires an entry from preset
keypad
Communication lost with POS
Stop button pushed or stop button
defective
Inlet pressures too low, too high
Product flow restriction
Defective Wayne Vac control board
or cables
Defective computer
Defective Wayne Vac Motor
Defective Wayne Vac Motor
Defective Wayne Vac control board
or cables
Defective computer
Set unit price
Set unit price on POS
Check setting of function 23.04
Check function 24.01
Verify data-link connection &
polarity to POS.
Verify stop button functionality
Check inlet pressures
Check product flow paths
(filters strainer, valves...)
Replace Wayne Vac control
board or cables
Re-Flash Program & Template
or Replace computer base
Replace Wayne Vac Motor
Replace Wayne Vac Motor
Replace Wayne Vac control
board or cables
Re-Flash Program & Template
or Replace computer base
65

Part No. 920525 Rev A

Hide quick links: