.06
Manufacturing default for Intelligent Pulser
.07
Stop button configuration
1 = Stop Both Sides
2 = Stop Side
F08- Side A Dispenser Type Configuration Part #1
Sub-function numbers are in the format: .XN where X = the selected configuration parameters and
N = the logical nozzle number 1-8 as follows:
.0N
Physical nozzle number assignment, 0-8, 0 = None assigned
.1N
Product type assignment, 1 = Non-blend, 2 = blend
.2N
Unit Price display assignment, 0-8, 0 = None assigned
.3N
Primary meter number assignment, 0-8, 0 = None assigned
.4N
Secondary meter number assignment, 0-8, 0 = None assigned
.5N
Primary valve number assignment 0-8, 0 = None assigned
.6N
Primary valve type, 1-3
1 = On/Off
2 = Fast/Slow
3 = Proportional
.7N
Secondary valve number assignment, 0-8, 0 = None assigned
.8N
Secondary valve type, 1-3
F09 - Side B Dispenser Type Configuration Part #1
Sub-function numbers are in the format: .XN where X = the selected configuration parameters and
N = the logical nozzle number 1-8 as follows:
.0N
Physical nozzle number assignment, 0-8, 0 = None assigned
.1N
Product type assignment, 1 = Non-blend, 2 = blend
.2N
Unit Price display assignment, 0-8, 0 = None assigned
.3N
Primary meter number assignment, 0-8, 0 = None assigned
.4N
Secondary meter number assignment, 0-8, 0 = None assigned
.5N
Primary valve number assignment 0-8, 0 = None assigned
.6N
Primary valve type, 1-3
1 = On/Off
2 = Proportional
.7N
Secondary valve number assignment, 0-8, 0 = None assigned
.8N
Secondary valve type, 1-3
F10 - Side A Dispenser type Configuration Part #2