Part No. 920525 Rev A - Wayne 3/VISTA series Service Manual

Blending and non-blending dispensers
Table of Contents

Advertisement

When the download is complete, the software executes a warm start which is just like a power cycle. If the laptop is
still connected and the laptop program is still running, the computer will re-enter maintenance mode prompting for
the passwords to be entered. At this point you can terminate the laptop program and disconnect the laptop.
After downloading a new template into the FLASH, a cold start must be done to transfer the new template from the
FLASH to the RAM.
6.4
STATISTICS LIST
The template controls access to statistics and sub-statistics. The template contains an access level table that
determines what functions each user has access to. Access levels are as follows:
l
Read and Write
l
Read only
l
No access
The following is a comprehensive list of defined statistics:
S01 - Side A Totals by Logical Nozzle
Sub-statistic numbers in the format '.TN'
T = totals type:
1 = Volume
2 = Total Money
3 = Credit
4 = Cash
5 = Serial Filling Mode Filling Count
6 = Stand Alone Mode Filling Count
N = logical nozzle number 0-8 (0 = None Assigned)
The least significant six (6) digits of the data value appear on the volume display. Higher order non-zero digits of the
data value, if present, appear on the money display. Leading zeros appear as blanks.
S02 - Side B Totals by Logical Nozzle
Sub-statistic numbers in the format '.TN'
T = totals type:
1 = Volume
2 = Total Money
3 = Credit
4 = Cash
5 = Serial Filling Mode Filling Count
6 = Stand Alone Mode Filling Count
N = logical nozzle number 0-8 (0 = None Assigned)
The least significant six (6) digits of the data value appear in the volume display with higher order non-zero digits of
the data value, if present, shown on the money display. Leading zeros appear as blanks.
S03 - Side A Error/Event Counter Totals
The money display is in the form of dashes and sub-statistic displays on the unit price display in the range 1-99
representing the set of error/events detectable by the program. The allowed range for the counter value is 0-255.
Note:
See Section 7 for a list of error codes.
June 2001
55

Part No. 920525 Rev A

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents